40
Installation and use MR16
8 – DEFAULT SETTINGS
System MR16 components go out of the default with following configurations:
Radio module with relay MR16
Function Programming
element
Default
Relay outputs 1÷8 polarisation
Jumpers J1÷J8
12 V
Relay output SAB polarisation
Jumper J9
12 V
Relay output RF SAB polarisation
Jumper J10
12 V
Relay output BATT polarisation
Jumper J11
12 V
Relay output ON/OFF polarisation
Jumper J12
12 V
Relay output SYS ST polarisation
Jumper J13
12 V
Acquisition
DIP switch A1
OFF = normal function
Acquisition
DIP switch A2
OFF = normal function
Arm test
DIP switch A3
OFF = normal function
Output relay 1÷8 operation mode
DIP switch A4
OFF = bistable
Output relay 1÷8 typology
DIP switch A5
OFF = NC
Output relay SYS ST typology
DIP switch A6
OFF = NC
Output relay ON/OFF typology
DIP switch A7
OFF = NC
Output relay SAB/SAB.R/BATT typology
DIP switch A8
OFF = NC
Arming operation, subordinated radio module status,
on outputs 1÷8
DIP switch B1
ON = outputs not
subordinated
Enable Jamming detection
DIP switch B2
OFF = disarmed
Enable supervision (radio sabotage)
DIP switch B3
OFF = disarmed
Enable buzzer
DIP switch B4
OFF = enabled
Enable physical sabotage alarm
DIP switch B5
OFF = enabled
Input S polarity
DIP switch B6
ON = positive polarity
Silence siren tamper for 1 hour
DIP switch B7
OFF = disabled
Silence sirens audio warnings
DIP switch B8
OFF = disabled
Microcontact DC500
Function Programming
element
Default
Count shutter detector pulses
Jumper J1
OFF = 5 pulses in 10 s
Internal reed contact
Jumper J2
OFF = enabled
Type of external detector
Jumper J3
OFF = either NC contact
or auxiliary input not
used