4.2.5 Configuration
Micro contact is configured via internal jumpers.
JP1
Shutter detector pulse count:
ON = alarm triggered after 8 pulses counted in 10 seconds
OFF alarm triggered after 5 pulses counted in 10 seconds
JP2
Internal reed contact
ON = disabled (only possible external detector is working)
OFF = enabled
JP3
External detector type:
ON = shutter rope detector
OFF = NC contact
Note: where auxiliary input is not use, leave default setting
At end of configuration, close back the device.
4.3 IR INDOOR DETECTOR IR500
Figure 16
4.3.1 Power supply
The device is provided with a pre-installed cell.
Remove the isolator pulling plastic tang on the rear side of the device.
After it was supplied, IR detector starts up an initialisation step which lasts about 2
minutes. During this step, its LED goes on blinking in colour red. When the LED goes
off, you can go on with acquisition step.
4.3.2 Acquisition
For IR detectors acquisition, see paragraph
4.2.2
.
Acquiring detection devices
.
LED and
programming / test key