MP200 Installation Manual
11
4.4 FUSE DESCRIPTION
F1: 2A 250V protection for non-self-powered sirens
F2: 1A 250V sensor power supply
F3: 2A 250V power supply self-powered sirens HPS+
F4: 1A 250V BUS 1 line protection
F5: 3A15 250V battery charging protection
4.5 DESCRIPTION OF LEDS
L7 RED
:
(ONLY MP200/256) BUS 3 CONTROL
if present OPTIONAL module - IT485
WHEN ON: BUS 3 FAILURE
L6 RED
:
BUS 2 CONTROL
if present OPTIONAL module - IT485
WHEN ON: BUS 2 FAILURE
L5 RED
:
BUS 1 CONTROL
WHEN ON: BUS 1 FAILURE
L4 YELLOW
:
TELEPHONE LINE ENGAGED
FLASHING: LINE ENGAGED
L3 RED
:
CONTROL
UNIT FAILURE SUMMARY
WHEN ON: FAILURE PRESENT
L2 GREEN
:
SYSTEM STATUS
WHEN ON: SYSTEM ACTIVE TOTAL
WHEN OFF: SYSTEM NOT ACTIVE
FLASHING: PARTIALLY ACTIVE
L1 GREEN: MAINS SUPPLY PRESENT /BATTERY CONTROL
WHEN ON: MAINS SUPPLY PRESENT
FLASHING: LOW UC BATTERY and any remote concentrator power supply unit
WHEN OFF: NO MAINS SUPPLY PRESENT
L7
F-1
A 250V LBC
F-2
A 250V LBC
F-1
A 250V LBC
F-2
A 250V LBC
F-3
A15 250V LBC