MP200 Installation Manual
4
2.0 System Components
2.1 MP 200/64 CONTROL UNIT
• 8 alarm zones, expandable to 64 using I/O concentrators (for 8 or 4 zones) connected to serial lines. As well as
alarm zone inputs there is also a tamper input and an electromechanical key input.
• Each alarm zone is freely programmable. Zone balancing may be programmed as single or double and thus offers
the possibility of defining a tamper alarm for each zone.
• The control unit has 11 individually programmable outputs, of which 8 are relay (free switch) and 8 are electric (open
collector).
The board manages 2 RS 485 type serial lines
(serial 2 is optional using an IT485 module), and each
line may connected to a maximum of 8 KP200D keypads, 8 DK4000M key readers, 4 DK4Z/4000M splitters and
up to 7 concentrators. In any case the maximum number of concentrators is limited to the number of zones that
can be managed by the control unit (64).
• The MP200/64 system may be subdivided into
12 different sectors
(or areas), to which the zones, outputs, keys,
codes, keypads, readers and splitters may be freely associated. Apart fom the two techincal codes envisaged, it
is also possible to manage up to 64 users, which may be codes or DK4000 digital keys, all programmable on a
hierarchical scale at various levels, and associable to one or more sectors.
• The RS232 serial connector on the board may be used for a direct local
printer link-up for online printing of alarm events, or to a Personal Com-
puter with FastLink dedicates software for up/download of programming
parameters.
• The standard PS228 power supply unit is able to offer maximum current
of 2.8 A. All supply outputs on the central board are protected against
short-circuiting by a fuse.
• The MP200 64-zone control unit is available in 2 models with different case sizes:
1.
the M200/64 has a medium-size sealed
metal case suitable for housing a 17 Ah
battery
2.
the MP200/64OM has a larger sealed
metal case suitable for housing a battery
no larger than 27 Ah.
12 A 27 Ah
PS22
PS22
12V - 17 Ah
PS28
PS28
Summary of Contents for MP 200
Page 19: ......