MP200 Installation Manual
18
FIG.1
FIG.2
In the space beneath the
control unit plate, there is
a set-up for installation of
2 concentrators for 4
zones (FIG.1) or for fitting
an 8-zone concentrator
(FIG.2)
PS28 FUSE
The PS28 is fitted with a type
F safety fuse: 3A15 250V
LBC on the 230V mains
input. Please do not open the
PS28 power supply unit
unless 230V~ mains power
has been disconnected.
5.2.1
Devices lay-out in the cabinet
Power Supply Connections
CONCENTRATOR
(OPTIONAL)
U1
U3
U2
U4 U5 U6 U7 U8 - +
HPA
NC
NC
NC
NO
NO
NO
C
C
C
HPS
L1
L2
L3
L4
L5
L6
U11-R5A
U10-R1A
U9-R1A
-
+
+
+BATT-
-
C
JP2
JP4
POWER SUPPLY
T/
A
Z8
F5
F1
F2
F3
F4
Z6
Z7
Z5
Z4
Z3
Z2
Z1
-+
+
+
-K
EY
BU
S1
SE
R
V
LB
LB
LA
LA
--
--
++
15
37
26
48
JP3
-
+
23
0
V
~
BATTERY
12V - 27 Ah
GROUND CONNECTION
PS28
Summary of Contents for MP 200