background image

DS80IM39-001B 

ENGLISH

 

The IM600 detector implements infrared (PIR) and microwave (MW) motion detection technology. The combination of the two 
detection methods considerably reduces the false alarm rate, employing PIR for initial detection and microwaves for confirmation 
before sending the alarm signal.  

Part identification 

1. Transmitter 

LED 

(red)

 

The LED indicator blinks to indicate that signals are being transmitted in the following 
situations. 

-  The Learn/Test button is pressed. 
-  The tamper switch is actuated or reset. 
-  Motion is detected in Test mode. 
-  Motion is detected in flat battery or open tamper conditions during normal operation. 

The LED does not blink if the tamper switch is closed, the battery is charged and the detector is 
not in Test mode. 
The LED blinks to indicate signal transmission, blinking rapidly twice upon receiving confirmation 
from the panel. 
The LED will blink every 4 seconds when the battery of the detector is flat. 

2.  Microwave detector LED (blue)

 

The LED lights up briefly when the microwave detector is in Test or in Microwave Test 
mode.  

3.  IR detection LED (green)

 

The LED lights up briefly when the microwave detector is in IR Test mode. 

4. Learn/Test 

button

 

5. Lens

 

6. Battery 

housing 

7. Supervision 

jumper

 

Jumper not fitted Supervision is always enabled. 

8.  Microwave test on/off jumper (JP3)

 

When the jumper is set to 

ON

, the detector is in microwave Test mode (see 

Microwave test mode

).

 

When the jumper is set to 

 OFF

, microwave Test mode is deactivated. 

(

default

)

 

9. Tamper 

switch 

The tamper switch is activated when it is lifted and reset when it is compressed (against a 
wall or a surface). 

10.  Microwave range trimmer 

The range is indicated on the right, with the arrow pointing to the set sensitivity level: 

- Turned 

clockwise

 it increases the detection range (up to 20 metres) 

- Turned 

anticlockwise

 it decreases the detection range (to a minimum of 3-5 metres) 

Default value

: set to a medium value, approximately 10 metres. 

11. Tamper hole 

The tamper switch must protrude from the hole on the rear cover 

12. Pre-cut area 

Features 

 

Motion detection 

 

The detector has an integrated PIR sensor and a microwave section. Motion is detected by the PIR sensor during normal 
operation. When the PIR sensor detects movements, microwave detection is activated to verify the detected motion. If 
both the PIR and the microwave confirm motion detection, the detector transmits the alarm signal. 

 

Set the microwave range trimming to adjust the detection range.  

 

When the trimmer is set to maximum, the detector has an approximately range of 12 metres and mounted at a height of 
1.9~2 m. 

 

When the trimmer is set to minimum, the detector has an approximately range of 5 metres and mounted at a height of 
1.9~2 m. 

 

Sleep Time 

 

The detector has a “

sleep time

” of approximately 1 minute to save energy. After having transmitted a detected movement, 

the detector will not transmit again for 1 minute; any further movements detected during the sleep period will extend the sleep 
period by another minute. In this way, continuous movements in front a detector will not drain the battery unnecessarily. 

 

Test mode 

The detector can be set to Test mode by pressing the specific Learn/Test button. Test mode lasts for 3 minutes and restarts 
from 3 minutes whenever the Learn/Test button is pressed. In Test mode, the sleep timer is deactivated and the LEDs light up 
when the detector detects a movement to notify the user.  

Summary of Contents for IM600

Page 1: ...or Innenraumdetektor mit doppelter Technologie Détecteur de mouvement double technologie Manuale d uso installazione e programmazione Installation programming and functions manual Installations programmier und gebrauchsanleitun Notice di installation programmation et utilization I EN DE FR ...

Page 2: ...icie 10 Trimmer portata microonde La portata viene indicata a destra con la freccia che punta al livello di sensibilità impostato Ruotando in senso orario si aumenta la portata di rilevamento fino a un massimo di 20 metri Ruotando in senso antiorario si diminuisce la portata di rilevamento fino a un minimo di 3 5 m Valore di default è impostato su un valore medio circa 10 metri 11 Foro antimanomis...

Page 3: ... ha due aree di pre rottura Quando il dispositivo è installato correttamente se un intruso rimuove a forza il rivelatore dalla posizione in cui è montato le aree si staccano dal coperchio posteriore e rimangono attaccate alla superficie di montaggio mentre viene rimosso il corpo principale del dispositivo attivando l interruttore tamper Apprendimento e installazione Preparazione 1 Orientare ed ins...

Page 4: ...fluenza di fattori esterni quali l altezza dell oggetto rilevato la gamma di rilevamento desiderata l area di installazione ecc L altezza di montaggio consigliata può essere regolata a seconda degli effettivi fattori ambientali di installazione Si consiglia di installare il rivelatore nelle seguenti posizioni Montare dove gli animali non possano accedere all area di rilevamento arrampicandosi sui ...

Page 5: ...l or a surface 10 Microwave range trimmer The range is indicated on the right with the arrow pointing to the set sensitivity level Turned clockwise it increases the detection range up to 20 metres Turned anticlockwise it decreases the detection range to a minimum of 3 5 metres Default value set to a medium value approximately 10 metres 11 Tamper hole The tamper switch must protrude from the hole o...

Page 6: ...t is mounted the areas are detected from the rear cover and remain attached to the mounting surface while the main body of the device is removed activating the tamper switch Learning and installation Preparation 1 Orient and insert the battery according to the polarity 2 The red LED will start blinking for 30 seconds to indicate that the detector is being initialised During initialisation the dete...

Page 7: ... be adjusted according to the actual environmental factors in the installation site It is advised to install the detector in the following positions Mount it where pets cannot access the detection area by climbing on furniture or other objects Avoid pointing the detector to stairs which can be climbed by pets Mount it in a position in which an intruder would normally cross the field of vision of t...

Page 8: ...wellentest Modus Ist der Jumper auf OFF gestellt wird der Mikrowellentest Modus deaktiviert Standard 9 Tamper Schalter Der Tamper Schalter Sabotageschutz wird aktiviert wenn er angehoben wird während er zurückgestellt wird wenn er gedrückt wird gegen eine Wand oder eine Oberfläche 10 Trimmer Mikrowellenreichweite Die Reichweite wird rechts mit dem Pfeil angegeben der auf das eingestellte Empfindli...

Page 9: ...uen Batterien eingelegt werden Überwachung Der Detektor sendet in regelmäßigen Abständen ein Überwachungssignal aus Ist das Steuergerät nicht in der Lage die vom Detektor übertragenen Überwachungssignale über einen voreingestellten Zeitraum zu empfangen wird ein Überwachungsalarm ausgelöst Tamper Schalter Der Detektor ist durch einen Tamper Schalter geschützt der aus der dafür vorgesehenen Öffnung...

Page 10: ...e LED einschaltet um zu überprüfen ob die Erfassungsabdeckung angemessen ist Wird beschlossen dass die Erfassungsabdeckung zufriedenstellend ist ist die Installation abgeschlossen Empfehlungen für die Installation Um die Leistungen zu optimieren muss der Detektor auf einer Höhe von 1 9 2 0 m montiert werden Seine Reichweite beträgt maximal 12 Meter wenn der Mikrowellensensor auf maximale Reichweit...

Page 11: ... im Erfassungsbereich vermeiden Den Detektor nicht direkt auf Wärmequellen wie Herde und Heizkessel richten und nicht über Heizkörpern installieren Vermeiden dass sich bewegliche Gegenstände im Erfassungsbereich befinden wie Vorhänge Wandbehänge usw Technische Daten Versorgungsspannung 1 3 V Lithium Batterie CR123A Batterieautonomie 4 Jahre normaler Wert kann je nach Verwendung schwanken Bidirekti...

Page 12: ...uré sur OFF le mode Test micro ondes est exclu par défaut 9 Interrupteur tamper L interrupteur tamper anti sabotage est activé quand il est soulevé et se désactive quand il est enfoncé contre une paroi ou une surface 10 Régulateur potentiomètre Trimmer portée micro ondes La portée est indiquée à droite avec la flèche orientée vers le niveau de sensibilité configuré Tourner dans le sens des aiguill...

Page 13: ...e détecteur dans un temps déterminé elle active une alarme de supervision Interrupteur tamper Le détecteur est protégé par un interrupteur tamper qui sort du trou du couvercle arrière et qui d habitude est enfoncé contre une paroi ou une surface d installation L interrupteur tamper est activé quand le détecteur est arraché de la surface d installation Parties prédécoupées Le couvercle arrière du d...

Page 14: ...a maison Dans le cas de chiens de taille supérieure à la moyenne monter le détecteur plus haut afin de préserver l immunité aux animaux domestiques Pour décider de la hauteur de montage du détecteur ne pas oublier de tenir compte des angles morts possibles Les angles morts sous le détecteur augmentent proportionnellement avec la hauteur de montage Attention les performances sont affectées par des ...

Page 15: ...z Portée détection 12 m max avec angle 110 Température de fonctionnement de 10 C à 45 C Dimensions 63 3 mm x 112 5 mm x 62 mm Poids 100g DECLARATION UE DE CONFORMITE SIMPLIFIEE Le soussigné URMET S p A déclare que l équipement radioélectrique du type DETECTEUR DE MOUVEMENT DOUBLE TECHNOLOGIE IM600 est conforme à la directive 2014 53 UE Le texte complet de la déclaration UE de conformité est dispon...

Page 16: ...16 DS80IM39 001B ELKRON Tel 39 011 3986711 Fax 39 011 3986703 www elkron com mail to info elkron it MADE IN TAIWAN ...