11. Power failure
After power failure or disconnecting from mains the position of the wing/wings is unknown
to the controller. The controller first works in a starting mode. The wings are mowing
slowly. A pressure relief of electromagnetic bolt occurs before every movement. The wings
close one after the other. When stopping at the end position (closed), the controller
recognises this position. The controller continues in its regular mode.
Note:
Emergency mode is possible during the starting mode.
12. Fault diagnosis
12.1. Error code on the display
An error is shown on the display as a code, when detected by the controller. The following
errors are recognised and displayed.
Display Error
E1
Photo-cell testing LSI failed
E2
Photo-cell testing LSA failed
E3
Testing safety contact profile SLA failed
E4
Testing safety contact profile SLZ failed
E5
Running distance exceeded (gate was stopped). Check end stoppers and re-
learn the running distance.
E6
The power supply limit for the external equipment 12V has been reached. The
power source load is too high. The controller is blocked.
E7
The power supply limit for the external equipment 24V has been reached. The
power source load is too high. The controller is blocked.
E8
The memory data has been lost / is faulty. The controller has to be re-learned.
E9
Error in storing of data on memory. Controller is faulty. Return for repairs.
EA
Error in the redundant detection of BS. Controller is faulty. Return for repairs.
EB
The controller detects one of the motor relays is faulty. Return for repairs.
EC
Measuring amplifier faulty. Return for repairs.
ED
The main wing pulser is faulty. Check the wiring between the opener and
controller.
EE
The pedestrian wing pulser is faulty. Check the wiring between the opener and
controller.
EF
Power supply Uext has a short cut.
OR
At least one wing is released. Check the
emergency release.