© 14.11.2005 ELKA-Torantriebe GmbH u. Co. Betriebs KG Page 29 TERRA 180/182 - 250/252 – 320/322
- When the automatic closure function is blocked it will be reactivated with a new
signal (BA or BT).
- When the lockage function for the photo-cells is activated, the automatic closure
function is blocked, as long as an obstacle is present between the photo-cells (see
sequence PB).
- When the gate hits an obstacle during closing and reversing is activated through
SLZ, the gate opens. When automatic closure is activated and the obstacle is not
removed, the gate will try to close twice. After hitting the obstacle for the second
time the gate will reverse for a short distance and stop.
- The counting will be erased when using BT, BA, or BZ.
8.1.7. Sequence P7: Automatic closure for pedestrian wing
When sequence
P7
is activated by button
LERN
, the present value for stay-open time for
the pedestrian wing is displayed. Possible values are
--
(not activated),
01
up to
299
(for
1s - 299s). The value can be increased using button
BT
and decreased using button
BTG
.
The decimal dots of the display are each equal to 100 ( one lit dot = 100 / two lit dots =
200).
Display (example) Corresponds to:
- -
Automatic closure is deactivated.
23
Automatic closure is activated. Stay-open time 23 seconds.
23.
Automatic closure is activated. Stay-open time 123 seconds.
2.3.
Automatic closure is activated. Stay-open time 223 seconds.
Table 16
Return to learning sequence using button
LERN
.
When using automatic closure the pedestrian wing closes automatically after the learned
stay-open time has elapsed. The stay-open time starts elapsing when the wing has
reached the position OPEN.
- When contact BS is opened, the automatic closure function is blocked.
- When the stay-open time has elapsed and the safety contact profile for direction
CLOSE (SLZ) is currently activated, the gate remains open. The elapsed stay-open
time will not be repeated. When the SLZ is not activated anymore and the stay-
open time has elapsed, the warning time prior to closing starts.
- When the automatic closure function is blocked it will be reactivated with a new
signal (BA or BT).
- When the lockage function for the photo-cells is activated, the automatic closure
function is blocked, as long as an obstacle is present between the photo-cells.
(See sequence PB)
- When the gate hits an obstacle during closing and reversing is activated through
SLZ, the gate opens. When automatic closure is activated and the obstacle is not
removed, the gate will try to close twice. After hitting the obstacle for the second
time the gate will reverse for a short distance and stop.
- The counting will be erased when using BT, BA, or BZ.