background image

ELK-M1XEP

Ethernet Interface

INSTALLATION 

MANUAL

828-397-4200 

Voice

828-397-4415 Fax

http://www.elkproducts.com

email: [email protected]

PO Box 100  •  Hwy. 70W  

• 

 Hildebran, NC 28637  •  USA

 

L524   3/10

All manuals and user guides at all-guides.com

all-guides.com

Summary of Contents for M1 ELK-M1XEP

Page 1: ...INSTALLATION MANUAL 828 397 4200 Voice 828 397 4415 Fax http www elkproducts com email info elkproducts com PO Box 100 Hwy 70W Hildebran NC 28637 USA L524 3 10 All manuals and user guides at all guide...

Page 2: ...irmware 16 Using the Virtual Keypad Application 17 Glossary of Terms 23 Troubleshooting Guide 24 IMPORTANT NOTICE The M1XEPhas been shipped with the non secure port enabled It is strongly recommended...

Page 3: ...be backed up with an adequately sized UPS Uninterruptible Power Supply in order for the equipment to con tinue operating during brief power outages Features and Specifications APPLICATION The ELK M1XE...

Page 4: ...amic DNS Support M1XEP PC Technical support from Elk Products Inc is limited to the setup and connection of the M1XEP inside the local network Connection to outside the local network may require assis...

Page 5: ...mming menu Menu 9 Choose Bus Module Enrollment Menu 1 and press the right arrow key to start the enrollment When the enroll ment is complete press the ELK or Asterisk key to exit Any required network...

Page 6: ...p 1 1 A router serving DHCP should not need any configuration to allow the M1XEP to connect inside the local network For communications outside the local network you will need to establish several ope...

Page 7: ...and 49151 are valid The recommended default port is 2101 This port should not be mapped outside the local network for security reasons If the port is not needed it should be disabled To disable the no...

Page 8: ...ave Usernames and Passwords are entered on this tabbed screen for use as a means of authentication while logging on to the M1XEPs secure connection port THESE ARE OPTIONAL If every Username and Passwo...

Page 9: ...his screen is where the email addresses and messages for email notification are entered Up to 16 addresses and messages can be stored Email addresses can be up to 48 characters long The message body m...

Page 10: ...he M1XEP setup Telephone account 2 corresponds with CS2 etc 1 Create a new telephone account in ElkRP To do this right click on the Telephones icon on the left side of the screen Choose New Telephone...

Page 11: ...a ID that the alarm trouble or event came from Information specific to OH2000E receivers The Account Number must be a decimal value not hexadecimal between 0001 and 9999 Line and Receiver numbers may...

Page 12: ...as letting you select a fully custom URL email services etc The free service allows you to select a URL in one of their sub domains For example DynDNS has nearly one hundred sub domains to choose fro...

Page 13: ...the following rules while doing this 1 Choose only a Stratum 2 server They are intended for public use Stratum 1 servers are reserved for use by governments large institutions and stratum 2 servers S...

Page 14: ...FTP or TCP Internet WAN to download firmware updates to the M1XEP 26 Web Browser Route outside to connect with web browser TCP through Internet WAN 80 Web Browser Route outside to connect with web bro...

Page 15: ...connected through a network router you will need to enter the IP address or URL for the entire local network The router must be programmed to allow outside traffic through a specific port For informat...

Page 16: ...ion to update the unit to Always select the latest version 6 Click the Update button The update may take several minutes Wait for the process to complete DO NOT INTERRUPT OR POWER DOWN THE UNIT DURING...

Page 17: ...ablished and ElkRP connects to the control the M1 Virtual Keypad will display Please Wait Panel has entered programming mode The M1 Virtual Keypad screen will be restored to normal when ElkRP disconne...

Page 18: ...Clicking Run will proceed to run the Java applet Clicking Cancel will abort the connection This screen will appear every time you connect unless you choose the Always trust content from this publishe...

Page 19: ...pad does not physically exist Hovering the cursor over the F keys causes their programmed identity name to be displayed Clicking an F key performs the function s programmed in the Keypad setup and or...

Page 20: ...on The On Off indicator will be Green when the device is On If there are too many lights to fit on one screen the word Next will illuminate along the bottom of the screen Click on Next to see addition...

Page 21: ...be selected Use the mouse to change any of the settings The Up arrows raise the setpoint values and the Down arrows lower the setpoint values 10 The Climate screen also has radio buttons along the to...

Page 22: ...stay on The Send button must be clicked to perform the desired command Outputs printed in Red type are currently On 11 Click the Tasks button to display the following screen This screen populates itse...

Page 23: ...ddress that is assigned to a node in a TCP IP network Static IP addresses are generally used for servers routers etc Dynamic IP Address an IP address that is automatically assigned to a client station...

Page 24: ...Highlight the M1XEP and click Use Selected If the M1XEP does not appear on the find screen refer to the troubleshooting steps above If there is a router firewall is between the PC and M1XEP it must po...

Page 25: ...another minute Central Station did not receive report Verify Telephone 1 corresponds with C S 1 etc Verify M1XEP Setup IP Address and Port Account Number Line and Receiver Verify Telephone Setup Forma...

Page 26: ...www elkproducts com All manuals and user guides at all guides com a l l g u i d e s c o m...