SX - Operating- & Service instruction - 8 074 667.02/02 - page 14
A 5
f-MAX limitation
0.0 - A63 Hz
FD: 0.0
A 6
f-MIN limitation
0.0 - A63 Hz
FD: 0.0
The frequency range which is defined by the values stored under parameter A4 (start frequency) and A63 (end
frequency) can be reduced via the parameters A5 and A6. The frequency inverter in this case only accepts set
values via the set value inputs or via the built in operator panel or the external control unit BE-4 which are within
this frequency range. As soon as the inverter gets a start command it runs to the frequency which is set via A6.
Remarks:
Remarks:
At input of 0 Hz for A5 and A6 or A5 < A6 the relevant parameter is not active.
Frequencies > 120 Hz can only be adjusted if parameter A64 „Maximum frequency“ is set to 400 Hz !!