System Menu
- 40 -
10.3
System: I/O Configuration
10.3.1
Input Functions
NOTE!
For safety reasons (fail-safe), the logic default setting of the inputs „extern
enable“, “external stop” and „switch endpos min/max“, is “LOW active.
External enable
The extern enable input is monitored during the positioning. If the input is activated, no positioning is
pos-sible respectively it will be cancelled with an error message.
External start
This input corresponds to the function of the button
External stop
This input corresponds to the function of the button
Setting the reference
If the parameter axis
X-/Y-axis
settings
reference mode is set to 2, 4, 6 or 8,
the actual value can be calibrated by activating this input:
Mode 2: Reference via external input (parameter axis
X-/Y-axis
distances
referenceval.)
Mode 4: Reference via target value + ext. input (Reference value: set target value)
Mode 6: Reference positive via external input
Mode 8: Reference negative via external input
Setup
Access to the system parameters
System-Times
Access to system parameters concerning times
I/O-configuration
Here the inputs and outputs can be assigned
Default parameter
Reset the parameters to factory settings
Input function
Input logic
Output function
Output logic