23
R41
Number of Lines in each Program Block
Enter the number of lines required per Program Block (1 – 99). The number of
Blocks will be calculated automatically.
Example :
Total number of Lines = 200
Number of Lines required per Block = 25 (enter 25 into R41).
Therefore the number of program blocks = 8
An entry of Lines over 99 will result in an error message “08” to flash.
R46
Program cycle pre-selection
This Register can be accessed without opening security code in R98.
The number of program executions can be entered in this register.
R47
Program cycle counter
This Register can be accessed without opening security code in R98.
The actual count value can be displayed and set in this parameter.
R48
Output Program cycle complete time
The length of this Program cycle end output is set in this parameter.
Setting 0.0 gives a maintained output at ST6 Pin 7-8.
R56
Multi edge counter
1 = pulses x 1
2 = pulses x 2 4 = pulses x 4
Entry of any other value will automatically select “1”
R64
Direction of Manual Buttons
Setting 0
Setting 1
Button 7 & 8
Backwards
Forwards
Button 9 & NR
Forwards Backwards
R69
Speed of going to Datum in First phase, in switched speed control mode
Value xxxxx0 = creep speed to limit switch
Value xxxxx1 = slow speed to limit switch
Value xxxxx2 = Fast speed to limit switch
Approach to the maker pulse always in creep-speed.