14
5.2
Setting and Changing Register Values
Example:
The Slowdown Point of 20.0 mm needs to be entered.
Assuming that Registers have been unlocked as above :-
Press R
The Nr Window flashes.
Press 1
1 (flashing) is displayed in Nr Window ie Register 01.
Press >
The existing value of R01 is displayed in Target window
Decimal
point
is
extinguished.
Press C
Clears old value to zero.
Key in “200”
Window shows 200 (ie 20.0 mm).
Press
E
The new value is memorised. All Windows are reset to
zero and Decimal Point is reinstated.
Any Register from 1 to 97 can be selected and changed in the above manner. If sequential Registers are
to be set, Press > twice instead of E and continue editing Register by Register.
Press E on completion.
It is possible to run the Controller with Registers unlocked, e.g. having set the Stop offset Register R03,
you may now execute a “Single” move and then go back to edit R03.
5.3
Locking of Registers
Once all the values have been set, it is necessary to relock the Registers to avoid accidental changes.
There are three methods to do so.
•
Select “R98” and type in (instead of security code) a “0” by the “C” button:
Type in :
R – 9 – 8 -
>
- C – E
•
Activate the “Reset” input
•
Switch “power down” and shortly after “power on”