13
4.4
Table mode (R8/4 =1)
If R8/4 is set to 1, then the controller operates in 99 selectable address Table mode.
Programming is exactly the same as in 4.2.2.
4.4.1 Operation in Table mode
An address line of the stored program can be called up and positioning effected to that setting.
Press Prog
Selects
Program
mode
Press T
Resets
Controller.
Press Nr
The Nr Window flashes “0”.
Key in (say) 58
“58” flashes in Nr Window.
Press >
The programd values of address
58
are displayed.
Press Start
The Axis executes the demanded settings.
5. Register Input
5.1
Unlocking Registers by Security Code
The values of Registers R1 to R97 can be changed after the Security Code 250565 has been entered into
Register R98. (Note that Registers R06, R07 and R40 are
accessible
without need for Security Code).
Accessing Registers can only take place when Controller is selected to Program mode. In Register input
mode, the decimal point is always at the correct position for the register resolution. All Registers are
entered in the Position Target window.
Use Button
E
to :
a) Store Register values
b) End editing at any point.
Press Prog
Controller is set to Program mode. LED “Prog” illuminates.
Press R
The Nr Window flashes
Key in “98”
Value 98 appears in Nr Window with “8” flashing.
Press >
The Target window shows “000000” without decimal point.
Press C
Clears display to zero.
Key in “250565
”
Display shows 250565 (The Security Code).
Press E
The Controller is now set to data entry mode. All Windows are
set to zero. Decimal point is reinstated.