15
6. Parameter table
Register Function
Adjustment-Range
Default Customer
01
Slow speed distance (forward)
0.1 mm
200*
02
Creep speed distance (forward)
0.1 mm
100*
03
Correction stop (forward)
0.1 mm
0
04
Spindle compensation
0.1 mm
50
05
Retract distance
0.1 mm
500
06*
Tool Width /Tool offset
0.1 mm
0
07*
Datum/reference value
0.1 m
1000
08
System Register 1
See Page 17
130000
09
Position reached pulse
0.1 s
10(0=held)
10
Backlash dwell time
0.1 s
10
11
Quantity reached pulse
0.1 s
10(0=held)
12
Tolerance window
0.1 mm
0
13
Min software limit
0.1 mm
0
14
Max software limit
0.1 mm
500000
15
Software limit disable
0,1,2,3
0
17 Display
brightness
0-15
10
18
System Register 2
See Page 20
000001
19
Encoder pulse monitor time
0.1 s
0
20 Decimal
point
3,0,2,1
0
21
Slow speed distance (only backwards)
0.1 mm
200*
22
Creep speed distance (only backwards)
0.1 mm
100*
23
Correction stop (only backwards)
0.1 mm
0
24
Window “forced loop”
0,1mm
0
25 Home
position
0,1mm
10000
28
System Register 8
See Page 22
000000
29
Time delay for drive enable
0.1 sec
10
30
Time “Program-end”
0.1 s
10
31
Closed loop inhibit time in Hand
0,1 sec
10
33
Power on mode
0,1 sec
10
34
Start delay time
0,1 sec
10
40*
Program Block selection
See Page 12
1
41
Number of lines in Prog Block
1 – 99
20
46*
Program counter Limit
1-99
0
47*
Program cycle counter
0 - 9999
0
48
Program Counter timer (pulse time)
0 - 9999
0
56
Encoder edge multiplier
1,2,4
1
64
Direction of manual buttons
0-1
0
69
Speed of automatic reference run
0-2
0
88
System Register 4
See Page 24
000000
90
Button enable in service mode
0,1,2
0
94
Inch / factor multiplier
0.0to 9.99999
100000
96
Pulse factor for encoder
100000
97
Inch / mm conversion mode
0,1,2,3
0
98 Security
code
250565
0
99 Service
-
-
0
* Logical sequence values such as these must always be present, regardless whether
3 speed, 2 speed or 1 speed drive is used.
P1 > P2 > P3 for 3 speed drive P1 = P2 > P3 for 2 speed or 1 speed drive.
Registers R6, R7 R40, R46 and R47 can be accessed and changed without need for Security Code.
The Registers R50 to 55, 57 to 63 and 65 to 68 are for analogue output only.