17
R08
System Register 1
This Register sets the basic operating functions of the unit.
Target window
Spindle compensation
0 = no spindle compensation
1 = negative spindle compensation
2 = positive spindle compensation
3 = negative spindle compensation in range of R24
4 = positive spindle compensation in range of R24
Output Relay Configuration
0 = 3 speed operation Creep ,slow, fast
1 = 2 peed Fo Backwards
2 = 2 speed Run + Reverse
3 = separate outputs - fast forward, slow forward, fast rev. slow rev.
4 = Fast only in reverse direction
5 = 3 speed Binary coded
6 = 3 speed operation, Fo Backwards
Program Memory
0 = Sequential Program
1 = Table selection
Datum/reference
0 = Datum to R7 with external pulse by key-switch
1 = Datum to Demand position window with external key-switch
4 = Datum to R7 by key-board only
Display windows (program mode only)*
0 = All windows in use
1 = Target alone
2 = Batch counter
3 = Batch c Abs/Incr.
Type of positioning
0 = Analogue positioning
1 = Fast/slow/stop
* Display selection for single mode see R28/6 (page 21)