R15
Software Limit / End Limits Selection
Software limits (R13 & R14) are active in accordance with the setting of R15/6
R13/R14 Min/Max software limits
Fault Message
Target < Limit R13
= 04
Target > Limit R14
= 05
xxxxx0
Both software limits active
xxxxx1
Min software limit (R13) inhibited
xxxxx2
Max software limit (R14) inhibited
xxxxx3
Both software limits (R13&R14) inhibited
External limit switches can be connected to the St4/3 (backwards) and at St4/4 (forwards)
xxxx0x
Both limits inputs active
xxxx1x
Min limit input (St4/3) inhibited
xxxx2x
Max limit input (St4/4) inhibited
xxxx3x
Both software limit inputs (St4/3 St4/4) inhibited
Notice: If these are not connected to limit switches they need to be connected Normally
closed (i.e. linked out).
R17 Display brightness
With the setting of this Parameter, the brightness of the displays can be altered.
0= dark, 15 = max brightness.