SECTION 4
STANDARD WAVEFORMS
The following standard waveforms are provided in the SW Series:
NAME DESCRIPTION
SCALE
FACTOR
FREQUENCY
RANGE
Clip0
A sine wave with the positive halfcycle clipped at 0V from
50 to 130°
1.0 40-5000
Hz
ClipPos
A sine wave with the positive halfcycle clipped from
50 to 130°
1.0 40-5000
Hz
ClipNeg
A sine wave with the positive halfcycle set to a 50%
negative value from 50 to 130°
1.0 40-5000
Hz
DC+
Used to operate the SW as a positive DC source
(true rms)
0.7071 N/A
DC-
Used to operate the SW as a negative DC source
(true rms)
0.7071 N/A
+DC with 3% ripple. Frequency of the ripple is deter-
mined by the programmed output frequency (true rms)
0.7071 40-5000
Hz
DcRip03-
-DC with 3% ripple. Frequency of the ripple is determined
by the programmed output frequency (true rms)
0.7071 40-5000
Hz
+DC with 10% ripple. Frequency of the ripple is deter-
mined by the programmed output frequency (true rms)
0.7071 40-5000
Hz
DcRip10-
-DC with 10% ripple. Frequency of the ripple is deter-
mined by the programmed output frequency (true rms)
0.7071 40-5000
Hz
Drop45
Sine with a drop-out above 0V from 45 to 60°
1.0
40-5000 Hz
DropNeg
Sine with a drop-out to -Vpeak from 4 to 50°
1.0
40-5000 Hz
DropPeak Sine wave with drop-out to 0V from 8 to 110°
1.0
40-5000 Hz
ExtrnDir
DC for use with System External direct input
1.0
40-5000 Hz
FlatTp05
Flat-top sine wave with 5% distortion (true rms)
0.9344
40-5000 Hz
FlatTp10
Flat-top sine wave with 10% distortion (true rms)
0.8894
40-5000 Hz
Operation Manual
4-1
Summary of Contents for SmartWave SW1750A
Page 2: ... ...
Page 4: ...Committed to Quality Striving for Excellence ii ...
Page 5: ...This page intentionally left blank iii ...
Page 8: ......
Page 31: ...SW 5250A SW 3500A SW 1750A Installation Operation Manual 2 5 Figure 2 3 SmartWave Rear Panel ...
Page 66: ...Operation SW 5250A SW 3500A SW 1750A 3 22 Operation Manual Table 3 1 Sequence Execute Menu ...
Page 90: ......