Operation
SW 5250A•SW 3500A•SW 1750A
3-44 Operation
Manual
10. Select
START
. Using the keypad, enter
45
, then press <
Enter
> to set the
starting phase angle to 45°.
11. Select
TIME
, enter
1
for a duration of 1 millisecond, then press <
Enter
>. Note
that the instrument automatically calculates the
STOP
phase angle value (in this
case, 66.6°).
12. Select
AMPL
, enter
10
for 10 volts, then press <
Enter
>.
13. Press
<
Menu
> to return to the WAVEFORM Menu.
LOAD
EDIT
VIEW
SAVE
DELETE
WAVEFORM
OUTPUT [OFF]
14. Select
VIEW
to view the scratchpad, then press <
Enter
>. A waveshape similar
to the one illustrated below should be displayed on the scratchpad.
2
2
1
2
2
1
0
90
180
270
WAVEFORM
OUTPUT [OFF]