Operation
SW 5250A•SW 3500A•SW 1750A
3-32 Operation
Manual
3.3.7.5 CONFIG
Sub-Menu
Pressing <
Enter
> to select CONFIG will display the System Configuration options.
BOOST
- Allows the Servo Boost circuit to be disabled during non-sequence operation.
This option is important when running a sequence at low voltage levels. See Section
1.12.2, Servo Boost, for a full explanation of the Boost function. The factory default
state is Boost ON. This option should be set to OFF when:
•
The RMS Servo is ON (Low Frequency = OFF) and
•
Sequence mode is being used with Exit mode set to “Program Menu.”
RESET CAL
– Resets calibration constants to default values. Enter a confirmation code
(2096) to activate this option. If you enter an incorrect code, the unit will beep and the
message “! INCORRECT RESET CODE” will be displayed, the code will be reset to 0,
and no changes will occur to the calibration constants.
T&MB OPT
– Displays firmware configuration for the Test & Measurement option. ON
indicates the Test & Measurement board is installed; OFF indicates it is not. This field is
for display purposes only.
SWAE OPT
– Displays firmware configuration for the Low Impedance option. ON
indicates the Low Impedance hardware is installed; OFF indicates it is not. This field is
for display purposes only.
USER
COMM
EXTERNAL
FAULTS
CONFIG
BOOST
ON
RESET CAL
0
T&MB OPT
OFF
SWAE OPT
OFF
SYSTEM
OUTPUT [OFF]
CONFIG Sub-Menu Status and Information Data:
Menu Item
Status and Information Line
BOOST
[System boost enable/disable]
RESET CAL
[Enter reset code]
T&MB OPT
[T&MB board installed?]
SWAE OPT
[Low impedance installed?]
Summary of Contents for SmartWave SW1750A
Page 2: ... ...
Page 4: ...Committed to Quality Striving for Excellence ii ...
Page 5: ...This page intentionally left blank iii ...
Page 8: ......
Page 31: ...SW 5250A SW 3500A SW 1750A Installation Operation Manual 2 5 Figure 2 3 SmartWave Rear Panel ...
Page 66: ...Operation SW 5250A SW 3500A SW 1750A 3 22 Operation Manual Table 3 1 Sequence Execute Menu ...
Page 90: ......