Energy consumption
EnergyConsumed[digit]
Available on fpc-01, fpc-02, fpc-04, fpc-05 devices
The widget EnergyConsumed[digit] represents the consumed energy as a
number.
To display the measured values, the elevator requires an energy sensor which
provides the display with the absolute consumption value via CANopen lift.
EnergyFedBack[digit]
Available on fpc-01, fpc-02, fpc-04, fpc-05 devices
The widget EnergyFedBack[digit] displays the fed energy as a number. To
display the measured values, the elevator requires an energy sensor that
provides the absolute value to the display via CANopen lift.
PowerSum[digit]
Available on fpc-01, fpc-02, fpc-04, fpc-05 devices
The widget PowerSum[digit] displays the current required energy as a number.
To display the measured value, the elevator needs an energy sensor which
provides the display with the absolute value via CANopen-Lift.
PowerSum[bar]
Available on fpc-01, fpc-02, fpc-04 devices
The widget PowerSum[bar] displays the energy currently required in the form of
a bar. The bar strikes from the center to the left when more energy is consumed
than fed or from the center to the right when more energy is fed than
consumed. The bar can be provided with an image or a specific color
depending on the direction of deflection.
In order to display the measured value, the elevator requires an energy sensor
that provides the display with the absolute value via CANopen lift.
© ELFIN Technology GmbH | flexyPage displays user manual | version 2.1.x | 2022-06