Page 17
Motion Detector Advanced User Manual
“Configuration” Command Class Parameters
Param
#
Size
Name
Available Values
Default
Value
04
This setting enables or disables motion detection.
01
Enable/Disable Motion Detection
00
(Motion Detection Disabled)
01
(Motion Detection Enabled)
01
(Motion
Detection
Enabled)
05
If Parameter 8 is enabled, this setting sets the light level below which the Motion Detector will send
BASIC_SET commands to Association Group 2 when motion is detected. For more information, see
“Group 2” on page 14.
02
Group 2 Ambient Light Threshold
00 05 ~ 03 E8
(5 ~ 1,000 in Lux)
00 64
(100 Lux)
06
After each motion event, the Motion Detector is disabled for the amount of time set by this
parameter before it can send out another “Motion Detected” Notification Report/Binary Sensor
Report. This value must be lower than the value of Parameter 2, and if this parameter is reset to
default settings, Parameter 2 will also be reset.
01
Retrigger Interval
01 ~ 08
(1 ~ 8 in seconds)
08
(8 sec)
07
This parameter sets the amount of time between each successive ambient light level reading that
is sent. This value must be less than the Wakeup Interval Time (which is 43,200 seconds or 12
hours by default.)
02
Light Sensing Interval
00 3C ~ 8C A0
(60 ~ 36,000 in seconds)
00 B4
(180 sec)
08
If this parameter is enabled, the Motion Detector will only send Basic Set commands to Associon
Group 2 if the ambient light level is below the value set in Parameter 05. For more information, see
“Group 2” on page 14.
01
Enable/Disable Group 2 Ambient
Light Threshold
00
(Group 2 Ambient Light Threshold Disabled)
01
(Group 2 Ambient Light Threshold Enabled)
0
(Ambient
Light
Threshold
Disabled)
Table 8 -
Motion Detector Configuration Parameters Continued