Page 14
Motion Detector Advanced User Manual
Compatible Command Classes
Command Class
Notes
Association V2 (85)
Group 1
Group 1 is the “Lifeline” group, which can hold five devices. The
Motion Detector sends this group a Notification Report and Binary Sen
-
sor Report whenever motion is detected and when it stops. It also sends
a Multilevel Sensor Report incrementally based on time (see Param 7,)
or when a relative change in light level is detected (see Param 9.) Final-
ly, the Motion Detector sends this group Battery Reports and a Device
Reset Locally notification to remove itself from the Z-Wave network.
Group 2
The Motion Detector sends a BASIC_SET command to Association Group
2 to directly trigger devices (like a siren, chime, etc.) when motion is de-
tected and when it stops. Optionally, the Motion Detector can be set to
only send this when ambient light levels fall below a predetermined level
(see Configuration Parameters 5 and 8.) See Configuration Parameters
2, 3, 5, and 8 for more details regarding Association Group 2.
Group 3
Group 3 supports up to 5 members and the Motion Detector sends it a
NOTIFICATION_REPORT when motion is detected and when it stops.
Group 4
Group 4 supports up to 5 members and the Motion Detector sends it a
SENSOR_BINARY_REPORT when motion is detected and when it stops.
Notification V4 (71)
The Motion Detector sends a Notification Report whenever motion is
detected. If no motion is detected for the amount of time set by Configu
-
ration Parameter 2, the device will send another Notification Report to
the main controller.
Returned Value:
00 00 00 FF 07 XX 00 00
V1 Alarm Type
: 00
(Unsupported)
V1 Alarm Level
: 00
(Unsupported)
Reserved
: 00
(Reserved)
Notification Status:
FF
(Unsolicited Reporting is Enabled)
Notification Type
: 07
(Home Security)
Event
:
Motion Detected
—08
(Motion Detected, Unknown Location)
No More Motion
—00
(Event Inactive)
Sequence/Reserved/Event Parameters Length:
00
Notification Event Parameters
: 00
(No Event Parameters)
Table 5 - Command Classes Continued