The company elero GmbH hereby declares that the AstroTec is in
conformity with the basic requirements and other relevant provi-
sions of the Directive 1999/5/EC.
Troubleshooting
GB-37
General declaration of conformity
GB-38
Troubleshooting
Problem
Cause
Remedy
Drive is not
Faulty connection.
Check the connection.
functioning.
Drive moves is wrong Faulty connection.
Exchange
V
and
B
direction.
wires in the power
supply unit.
Astro programme
1. Date is incorrect.
1. Set correct date.
doesn’t function
2. Wrong city or wrong 2. Set correct city
properly.
latitude/longitude
or exact degrees
setting.
latitude / longitude.
3. Holiday function is
3. Switch holiday
switched on.
function off.
4. Astro shift is set.
4. Adjust astro shift.
The AstroTec does not The sliding switch
Move the sliding
carry out the
is set to “HAND ”.
switch to “AUTO ”.
switching commands.
The AstroTec does not Holiday function is
Switch holiday
carry out the
switched on.
function off.
switching commands
precisely.
The sun and twilight
No light sensor is
Check the light
parameters cannot be connected or the light
sensor, connecting
changed and/or
sensor and/or the
cable and
are not displayed.
connecting cable is
connector plug.
faulty.
Roller shutter does
1. The set running time 1. Adjust the running
not move to the end
is not long enough.
time in the function
limit.
menu.
2. No end limit position 2. Set the end limit
is set.
position using
the setting menu
PROG1/2.
GB