Programming
GB-30
Programming
GB-29
SETTING
ENGLISH GB/ASTRO SHIFT
v b
(Language, astro shift)
SETTING
PROG 2 END LIMIT
(Time/position programming)
See
previous page
See
next page
PROG2
END LIMIT
PROG2
INTERMEDIATE
POSITION
PROG2
VENTILATION
OK
OK
OK
+/–
+/–
Note:
This dialog window will only be displayed if a time is set in
PROG2.
You have confirmed the PROG1 END LIMIT menu level.
PROG2 END LIMIT will appear.
1. You can select PROG 2 END LIMIT, PROG 2 INTERMEDIATE
POSITION and PROG 2 VENTILATION/REVERSE using the
+/-
button
2. Confirm your selection by pressing
OK
.
The function PROG2 POSITION has now been set.
Please read on for further programming options using the
SETTING menu.
GB
See
previous page
TEST MODE
ON/OFF
ENGLISH GB
ASTRO
SHIFT
v
OK
See
next page
OK
OK
+/–
+/–
+/–
OK
+/–
ASTRO
SHIFT
b
Note:
The TEST MODE menu level will only be displayed if a light
sensor is connected to the device.
You have confirmed the PROG2 END LIMIT menu level.
TEST MODE ON/OFF will appear.
1. You can activate or deactivate the TEST MODE (ON/OFF) using the
+/-
button.
2. Confirm by pressing
OK
. ENGLISH GB will appear.
Note:
To exit from TEST MODE, press the
OK
button in operating
mode.
3. You can set the language required using the
+/-
button.
4. Confirm the language selected by pressing
OK
.
ASTRO SHIFT
v
will appear.
5. You can set the required astro shift
v
(max. +/- 120 mins.) using
the
+/-
button.
6. Confirm by pressing
OK
. ASTRO SHIFT
b
will appear.