Operating and assembly instructions RD-ATEX

www.elektror.com

016327 02.18/06

CONTENTS

1     MACHINE SPECIFICATIONS
2    INFORMATION ON TRANSPORT AND HANDLING
3    INFORMATION ON PUTTING INTO SERVICE
4    INSTRUCTIONS FOR OPERATION AND USE
5    INSTRUCTIONS FOR MAINTENANCE
6 SAFETY-RELATED 

INFORMATION 

 

ON TAKING OUT OF OPERATION AND REMOVAL

7  LIABILITY AND EXCLUSION OF LIABILITY
8    DECLARATION OF CONFORMITY
9    TECHNICAL SPECIFICATIONS

These operating and assembly instructions should be avail-

able to operating personnel at all times. Read these operat-

ing and assembly instructions carefully before installing and 

putting the blower into service. 

Subject to change without prior notice. If in any doubt, the 

manufacturer should be consulted. This document is protect-

ed by copyright. It must not be disclosed to third parties with-

out our express written consent. Any form of duplication or 

recording and storage in electronic equipment is forbidden.

1 MACHINE SPECIFICATIONS

Please refer to the cover sheet for our address.

For the area of validity of these Operating and Assembly In-

structions, please refer to the Declaration of Installation Con-

formity.

The technical speci

fi

 cations on page 21 ff. apply to the stand-

ard version. Your blower‘s speci

fi

 cations may differ from these 

speci

fi

 cations (refer to nameplate). If this is the case, please 

refer to the enclosed, additionally applicable documents or 

your own applicable Operating and Assembly Instructions.

Nameplate

For connection, maintenance and ordering of spare parts, 

only the data on the blower nameplate is de

fi

 nitive. Also refer 

to the nameplate for the serial number of the appliance and 

its year of manufacture. Electrical data is provided on the 

motor nameplate. The blower nameplate applies to the com-

plete blower. The motor nameplate is subordinate to this. 

1.1 Designated use

The operation of an explosion-protected Elektror blower, in 

accordance with the 94/9/EC directive, is only permitted in 

countries or in economic sectors where this directive is valid 

or is not restricted, as well as legally recognised.
Conversion and modi

fi

 cations to operational blowers are im-

permissible.
The units described in these operating and assembly instruc-

tions correspond to the category, type of ignition protection, 

temperature class, etc. speci

fi

 ed on the nameplate. 

 

The following section lists the unit categories according to 

ATEX:

Category 3G 

 

The equipment is so designed and constructed as to 

prevent ignition sources during normal operation in areas 

where an explosion hazard due to gases (G) exists.

Category 3D

 

The equipment is so designed and constructed as to 

prevent ignition sources during normal operation in areas 

where an explosion hazard due to dust (D) exists.

Category 2G

 

The equipment is so designed and constructed as to pre-

vent ignition sources even in the event of disturbances in 

areas where an explosion hazard due to gases (G) exists.

Category 2D

 

The equipment is so designed and constructed as to prevent 

ignition sources even in the event of disturbances in areas 

where an explosion hazard due to dust (D) exists.
Units according to category 1G or 1D (for Zone 0, Zone 20) 

are not included in the scope of supply of Elektror airsystems 

gmbh.

As indicated on the nameplates, the units may be suit-
able for use in one of the following areas with potentially 

explosive atmospheres (for an exact de

fi

 nition refer to: 

EN 1127-1):
Zone 2 / 22

 

Areas in which an explosive atmosphere consisting of a mix-

ture with air of 

fl

 ammable substances in the form of gas, va-

pour, mist or dust is not likely to occur in normal operation 

but, If it does rarely occur, then it will persist for a short period 

only.

Zone 1 / 21

 

Areas in which an explosive atmosphere consisting of a 

mixture with air of 

fl

 ammable substances in the form of gas, 

vapour, mist or dust is likely to occur in normal operation oc-

casionally.

Explosion group II

 

Electrical equipment intended for areas not endangered by 

fi

 redamp (other than mining).

Installation type B or C

 

Blower connected on one end only, that is on pressure end or 

intake end (compare DIN 24163). 

The same potentially explosive atmosphere is present inside 

and outside the blower. 

Installation type D

 

Blower connected on intake and pressure end. For unsealed 

Elektror units and equipment, this application is limited to 

cases in which the same potentially explosive atmosphere is 

present inside and outside the blower.
Ignition sub-group IIA and IIB (cf DIN EN 50014).

Temperature classes:

Units according to Directive 94/9/EC are classi

fi

 ed into class-

es of max. permissible surface temperatures (temperature 

classes). Information regarding the temperature class is on 

the nameplates of the units. The highest permissible surface 

temperature class indicated is applicable only if the product 

is used for its designated purpose.
Blower section and motor may have individual nameplates. 

The lowest category and temperature class indicated for any 

component is also applicable for the entire unit.

Labelling examples:

       II 3G c T3 – Example of category speci

fi

 cation and  

 

    design safety as per EN 13463-5

EEx de IIB T4 – Example of a speci

fi

 cation for a type 

 

    of ignition protection

Summary of Contents for RD 62

Page 1: ...uck ventilatoren Betriebs und Montageanleitung Explosionsgeschützte Ausführung gemäß Richtlinie 2014 34 EU DE Elektror Medium Pres sure Blowers Operation and assembly instruc tions Explosion protect ed design according to directive 2014 34 EC EN Instructions de sevice et de montage des ventila teurs moyenne pression Version antidéflagrante en conformité avec la directive 2014 34 CE FR Instrukcja o...

Page 2: ...etc Im Folgenden werden die Geräte Kategorien nach ATEX aufgeführt Kategorie 3G Konstruktive Gerätegestaltung zur Vermeidung von Zünd quellen bei Normalbetrieb mit Explosionsgefahr durch Gas G Kategorie 3D Konstruktive Gerätegestaltung zur Vermeidung von Zünd quellen bei Normalbetrieb mit Explosionsgefahr durch Staub D Kategorie 2G Konstruktive Gerätegestaltung zur Vermeidung von Zünd quellen auch...

Page 3: ...t werden Förderung von Fremdkörpern Adiabatische Kompression und Stoßwellen Blitzschlag elektromagnetische Wellen ionisierende Strahlung Ultraschall Sonderausführungen Können für den Einsatz außerhalb der in dieser Anleitung beschriebenen Anwendungen auf Anfrage zur Verfügung stehen Bei Sondergeräten sind die Hinweise in den zusätz lich beigelegten Zusatzbetriebs und Montageanleitungen zu beachten...

Page 4: ...lektror gelieferten Umrichtertypen sind folgende Drehzahlstellbereiche zulässig bei 50 Hz Ausführung 5 50 Hz bei 60 Hz Ausführung 5 60 Hz bei Nennfrequenzen größer 60 Hz darf eine Mindestfrequenz von 20 Hz nicht unterschritten werden bei Betrieb mit Temperatursperre darf eine Mindestfrequenz von 35 Hz nicht unterschritten werden Verhalten nach erfolgter Zündung Explosion oder sons tiger Havarie Ha...

Page 5: ...tung des Kaltleiterfühlers durch den Fre quenzumrichter ist in ATEX Anwendungen im Regelfall nicht zulässig hierzu bitte die Angaben des Umrichter Herstellers unbedingt beachten Hinweis Bei Betrieb des Antriebsmotors mit Frequenzum richter ist zusätzlich folgendes zu Beachten Es dürfen nur Motoren am Frequenzumrichter betrieben werden die mit EExde Motor für den Frequenzumrichterbetrieb geeignet s...

Page 6: ...t werden Der Anschluss des Motors erfolgt nach dem Schaltbild im Klemmenkasten und den einschlägigen örtlichen Bestim mungen Die Anschlusskabel sind möglichst kurz möglichst ohne Zwischenklemmstellen und ohne Steckvorrichtungen zu verlegen Die Motor und PTC Auswertekabel zwischen Motor und Frequenzumrichterausgang müssen mit abgeschirmten Kabeln ausgeführt entsprechend den aktuellen Vorschrif ten ...

Page 7: ...nweis Keinesfalls darf am Umrichter eine höhere Frequenz Drehzahl eingestellt werden als die Frequenz fB welche auf dem Leistungsschild angegeben ist da entweder der Motor überlas tet wird oder durch die überhöhte Drehzahl der Ventilator zerstört werden kann Es darf ebenfalls am Umrichter kein sogenannter Boost eingestellt werden da eine übermäßig starke Erwärmung des Antriebsmotors die Folge wäre...

Page 8: ...Fälligkeit der Kugellager ist allerdings von den Be triebsbedingungen abhängig und kann später aber auch erheblich früher erforderlich werden Es liegt im Sicherheits Ermessen des Betreibers den Zeitpunkt für den Austausch eigenverantwortlich festzulegen 5 4 Abdichtungen und Radial Wellendichtringe Abdichtende Bestandteile und Radialwellendichtringe sind aus Sicherheitsgründen mindestens bei jeder ...

Page 9: ...ntilators ist für die Bestellung einiger Ersatzteile entscheidend Ermitteln Sie die Stellung Ihres Venti lators durch Blick auf die Saugseite Bestellen Sie Ersatzteile zur Drehrichtung passend Rechtsdrehend Ar bis Dr Linksdrehend El bis Hl Für Sicherheit und Gesundheitsschutz im Betrieb sowie den sicheren störungsfreien Betrieb trägt nach geltender Rechts lage der Betreiber Verantwortung Nach der ...

Page 10: ...06 42 EG entspricht Die folgenden harmonisierten Normen wurden angewandt DIN EN 12100 2011 Sicherheit von Maschinen Allgemeine Gestaltungsleitsätze Risikobeurteilung und Risikominderung ISO 14694 2003 Industrieventilatoren Technische Vorschriften für die Wuchtgüte und Vibrationspegel DIN EN 1127 1 2011 Explosionsfähige Atmosphären Explosionsschutz Teil 1 Grundlagen und Methodik DIN EN 13463 1 2009...

Page 11: ...2740 230 400 50 1 68 0 97 0 37 19 3 68 75 RD 4 13 5 2200 3000 2770 230 400 50 2 48 1 43 0 55 19 9 71 78 RD 5 18 0 2100 3000 2770 230 400 50 2 48 1 43 0 55 24 9 72 78 RD 6 21 0 2500 3000 2810 230 400 50 3 03 1 76 0 75 25 8 75 81 RD 62 30 0 3000 3000 2850 230 400 50 4 75 2 75 1 3 38 7 78 81 RD 64 35 0 3100 3000 2870 230 400 50 6 65 3 85 1 85 42 3 79 85 RD 65 40 0 2300 3000 2870 230 400 50 9 0 5 2 2 ...

Page 12: ...during normal operation in areas where an explosion hazard due to gases G exists Category 3D The equipment is so designed and constructed as to prevent ignition sources during normal operation in areas where an explosion hazard due to dust D exists Category 2G The equipment is so designed and constructed as to pre vent ignition sources even in the event of disturbances in areas where an explosion ...

Page 13: ...nd shock waves lightning electromagnetic waves ionising radiation ultrasound Special designs Can be provided upon request for applications in conditions beyond those described in these instructions In the case of special equipment the enclosed supplementary operating and assembly instructions must be observed and adhered to The supplementary instructions differ in certain respects from these Opera...

Page 14: ...andling Prior to installation and putting into service check all parts for transit damage A damaged blower is a potential safety hazard and therefore should not be put into service Do not store the blower unprotected in the open protect against moisture Attach hoist securely Only use hoists and load suspensi on devices with sufficient load carrying capacity Secure the route of transportation 3 INF...

Page 15: ...the motor nameplate are definitive A frequency converter with no or unsuitable explosion protection must not be operated in the ATEX area of the motor blower The safety instructions as well as the operating and maintenance instructions included by the manufacturer of the drive motor and of the blower must be observed in all circumstances In particular specifications on the maxi mum cable lengths c...

Page 16: ...oof encapsulation Further information is available in the motor documentation At the converter the voltage frequency assignment must be set according to the diagram UB und fB see nameplate Never set a higher frequency speed at the converter than the max frequency fB indicated on the nameplate Otherwise the motor can be overloaded or the blower can be destroyed due to the excessive speed of the blo...

Page 17: ... trial grids If the converter is connected directly to and oper ated on a public grid then additional interference suppres sion measures such as a mains choke must be built into the mains feeder For further information refer to the converter manufacturer s specifications 5 INSTRUCTIONS FOR MAINTENANCE 5 1 Basic information Before and after maintenance service measures repairs or replacement of par...

Page 18: ...Cleaning or maintenance must not damage or alter the ap pliance and its component parts to the detriment of health and safety protection and must not for instance affect the balancing of the impeller No agents tools are to be used for cleaning that may lead to electrostatic charge build up or may give rise to other risks 5 9 Repair and Replacement of Parts of Elektror ATEX Products When using spar...

Page 19: ...d all oth er electrical engineering work in connection with taking the blower out of operation must be referred to a qualified electri cian The blower may only be dismantled after all rotating parts have come to a standstill and a safeguard has been provided to prevent restarting Dismantling and removal must be performed in accordance with the guidelines set out in section 2 1 Transportation and h...

Page 20: ...led complies with the provisions of the Machinery Directive 2006 42 EC The following harmonised standards have been applied DIN EN 12100 2011 Safety of machinery General principles for design Risk assessment and risk reduction ISO 14694 2003 Industrial fans Specifications for balance quality and vibration levels DIN EN 1127 1 2011 Explosive atmospheres Explosion prevention and protection Part 1 Ba...

Page 21: ...1 0 2000 3000 2740 230 400 50 1 68 0 97 0 37 19 3 68 75 RD 4 13 5 2200 3000 2770 230 400 50 2 48 1 43 0 55 19 9 71 78 RD 5 18 0 2100 3000 2770 230 400 50 2 48 1 43 0 55 24 9 72 78 RD 6 21 0 2500 3000 2810 230 400 50 3 03 1 76 0 75 25 8 75 81 RD 62 30 0 3000 3000 2850 230 400 50 4 75 2 75 1 3 38 7 78 81 RD 64 35 0 3100 3000 2870 230 400 50 6 65 3 85 1 85 42 3 79 85 RD 65 40 0 2300 3000 2870 230 400...

Page 22: ...c mentionnés sur la plaque signalétique de l appareil Ci après figurent les catégories d appareils selon ATEX Catégorie 3G Appareil conçu de façon à éviter des sources d inflamma tion en fonctionnement normal impliquant un risque d explo sion dû à la présence de gaz G Catégorie 3D Appareil conçu de façon à éviter des sources d inflamma tion en fonctionnement normal impliquant un risque d explo sio...

Page 23: ...ur réseau à tension assignée 5 et fréquence assignée ils ne sont en aucun cas prévus pour fonction ner avec des variateurs de fréquence Un fonctionnement dans les conditions prévues exclut les applications suivantes Conditions ambiantes particulières p ex une tempéra ture ambiante supérieure à 40 C sur le lieu de montage d utilisation des dépôts de poussières des vibrations sur le lieu de montage ...

Page 24: ... défavorables une protec tion contre le bruit sera nécessaire il est recommandé à l exploitant d effectuer les mesures La protection contre le bruit sera effectuée par l exploitant dans le but de ne pas dépasser dans le périmètre du ventilateur les seuils admis par la réglementation sur les lieux de travail La protection contre le bruit de quelque type que ce soit ne doit en aucun cas conduire à u...

Page 25: ...rante marqués EEx de II2GD T4 135 C Pour les appareils ATEX destinés au fonctionnement avec variateurs de fréquence il faut que la sonde thermique ther mistance CTP montée dans le moteur soit branchée à un appareil de surveillance adapté et autorisé pour les applica tions ATEX et qu elle soit analysée Les relais de déclenchement répondant à la directive IEC 61508 sont adaptés en cas de défaillance...

Page 26: ... échéant Prière de s adresser à ce sujet aux four nisseurs de variateurs de fréquence Dans ce cas prévoir un espace suffisant dans l armoire électrique au cas où des éléments filtrants supplémentaires étaient nécessai res Avis En cas de livraison d un pack de variateur de fréquence ce dernier ne convient pas pour l installation et le fonctionnement dans un environnement ATEX et doit impérativement...

Page 27: ...e sécurité décrites des paragraphes 1 2 à 1 10 Pendant le fonctionnement si le courant de référence du moteur de commande est dépassé vérifier si la tension et la fréquence du réseau concordent avec les données techni ques de l appareil Après des interruptions produites par le système de protec tion déclenchement du disjoncteur protecteur réaction de l évaluateur CTP sur les moteurs à thermistance...

Page 28: ...ui même la périodicité du nettoyage de l inspection et de la maintenance en fonction des heures de service des sollicitations et des conditions d utilisation Révision et entretien immédiats Ils doivent être effectués en cas de vibrations et d oscilla tions et de réduction de la puissance de ventilation Remarque Nous recommandons de faire réparer le matériel par le fabricant En cas de réparations m...

Page 29: ...ons s appliquent dans tous les États membres et doivent être respectées de manière similaire En dehors du territoire de l Union européenne l acheteur le commerçant et l utilisateur doivent respecter les lois les prescriptions et les règlements des autorités en matière de protection contre l explosion qui s appliquent au lieu d utilisa tion du produit ATEX correspondant de la Sté Elektror Si des co...

Page 30: ...nt après que toutes les pièces en rotation sont à l arrêt et qu une remise en marche n est plus possible Le démontage et le transport doivent se faire suivant les consignes données dans 2 1 Transport et manutention L élimination doit être effectuée selon les règles en vigueur 7 RESPONSABILITE ET EXCLUSION DE RESPONSABILITE L exploitant est responsable de l exploitation de l appareil dans les condi...

Page 31: ... aux dispositions de la Directive Machines 2006 42 CE Les normes harmonisées suivantes ont été appliquées DIN EN 12100 2011 Sécurité des machines Principes généraux de conception Appréciation du risque et réduction du risque ISO 14694 2003 Ventilateurs industriels Spécifications pour l équilibrage et les niveaux de vibration DIN EN 1127 1 2011 Atmosphères explosives Prévention de l explosion et pr...

Page 32: ...37 0 97 0 37 17 8 72 76 RD 2 11 0 2000 3000 2740 230 400 50 1 68 0 97 0 37 19 3 68 75 RD 4 13 5 2200 3000 2770 230 400 50 2 48 1 43 0 55 19 9 71 78 RD 5 18 0 2100 3000 2770 230 400 50 2 48 1 43 0 55 24 9 72 78 RD 6 21 0 2500 3000 2810 230 400 50 3 03 1 76 0 75 25 8 75 81 RD 62 30 0 3000 3000 2850 230 400 50 4 75 2 75 1 3 38 7 78 81 RD 64 35 0 3100 3000 2870 230 400 50 6 65 3 85 1 85 42 3 79 85 RD ...

Page 33: ...016327 02 18 06 33 Instructions de service et de montage RD ATEX www elektror fr FR POUR VOS NOTES ...

Page 34: ... tabliczce znamionowej urządzenia tj kategorii typowi ochrony prze ciwwybuchowej klasie temperaturowej itd Poniżej przedstawiono kategorie urządzeń według dyrekty wy ATEX Kategoria 3G Urządzenie jest tak zaprojektowane i wykonane aby za pobiec powstawaniu źródeł zapłonu podczas normalnego działania w obszarach zagrożonych wybuchem gazów G Kategoria 3D Urządzenie jest tak zaprojektowane i wykonane ...

Page 35: ...u chowej EEx e są przewidziane wyłączenie do pracy z zasilaniem sieciowym o napięciu znamionowym 5 i częstotliwości znamionowej i w żadnym wypadku nie są przewidziane do pracy z przemiennikiem częstotliwości Użytkowanie zgodnie z przeznaczeniem wyklucza Szczególne warunki otoczenia takie jak np temperatura otoczenia w miejscu montażu eksploatacji przekraczająca 40 C osadzanie pyłu wstrząsy w miejs...

Page 36: ...y poziom hała su podany jest w tabeli na stronie 44 W określonych niekorzystnych przypadkach wymagana jest izolacja dźwiękowa użytkownikowi zaleca się przeprowa dzenie odpowiednich pomiarów Izolacja dźwiękowa musi być wykonana przez użytkownika aby nie doszło do prze kroczenia prawnie dopuszczalnych wartości maksymalnych na stanowiskach pracy w otoczeniu wentylatora Jakiegokolwiek rodzaju izolacja...

Page 37: ...otyczące pracy z przemiennikiem częstotliwości patrz podrozdział 3 3 1 do 3 3 4 3 3 1 Szczególne wskazówki dotyczące pracy wentylatorów ATEX z przemiennikiem częstotliwości Uwaga Z przemiennikiem częstotliwości mogą pracować tylko silniki ognioszczelne i wzmocnione ozna czone EEx de II2GD T4 135 C W przypadku zespołów ATEX dostosowanych do pracy z przemiennikiem częstotliwości czujnik temperatury ...

Page 38: ...ie ręcznym Jeśli producent silnika nie podaje innych danych to napięcie zasilania przemiennika nie może przekraczać 400 V a długość kabla 20 m W przypadku większych długości kabla wyższych napięć zasilania i lub specjal nych wymagań EMC należy w razie potrzeby zastosować odpowiednie dodatkowe środki zaradcze W tej sprawie należy zwrócić się do dostawcy przemiennika W przy padku dodatkowo wymaganyc...

Page 39: ...ŻYTKOWANIU 4 1 Zasady podstawowe Prosimy przestrzegać wskazówek zawartych w podrozdziale 1 1 dotyczących użytkowania maszyny zgodnie z jej prze znaczeniem oraz zasad bezpieczeństwa opisanych w pod rozdziałach od 1 2 do 1 10 Jeśli podczas pracy zostanie przekroczony prąd znamiono wy silnika napędowego należy sprawdzić czy wartość na pięcia sieciowego i częstotliwości sieciowej odpowiada para metrom...

Page 40: ...lony personel techniczny Oprócz instrukcji obsługi da nego urządzenia oraz instrukcji i zaleceń dla całej instalacji należy przestrzegać następujących zasad 5 2 Częstotliwość przeglądów i konserwacji W zależności od godzin pracy obciążeń i warunków pra cy użytkownik musi sam określić wymaganą częstotliwość czyszczenia przeglądów i konserwacji Natychmiastowy przegląd i konserwacja W przypadku wystą...

Page 41: ...e Na terenie Republiki Federalnej Niemiec są do przede wszyst kim wytyczne TRBS 1201 3 oraz 14 6 rozporządzenia BetrSichV Na obszarze Unii Europejskiej we wszystkich państwach członkowskich obowiązują odpowiednie prawne i urzędowe wytyczne i regulacje które w tym samym zakresie muszą być przestrzegane Poza Unią Europejską nabywca sprzedawca i użytkownik musi przestrzegać praw przepisów i regulacji...

Page 42: ... specjalistów elektryków Demontaż dozwolony jest dopiero wtedy gdy całkowicie zatrzymają się wszystkie części wirujące i nie jest możliwe ponowne uruchomienie W odniesieniu do demontażu i odtransportowania muszą być przestrzegane zalecenia podane w podrozdziale 2 1 Trans port i obchodzenie się z maszyną Utylizacja maszyny musi być przeprowadzona w sposób fa chowy 7 ODPOWIEDZIALNOŚĆ I WYŁĄCZENIE OD...

Page 43: ...owane DIN EN 12100 2011 Bezpieczeństwo maszyn Pojęcia podstawowe ogólne zasady projektowani analiza ryzyka i redukcja ryzyka ISO 14694 2010 Wentylatory przemysłowe Przepisy techniczne dotyczące jakości wyrównoważenia i poziomu drgań DIN EN 1127 1 2011 Atmosfery wybuchowe Zapobieganie wybuchowi i ochrona przed wybuchem część 1 Pojęcia podstawowe i metodyka DIN EN 13463 1 2009 Urządzenia nieelektryc...

Page 44: ... 0 37 17 8 72 76 RD 2 11 0 2000 3000 2740 230 400 50 1 68 0 97 0 37 19 3 68 75 RD 4 13 5 2200 3000 2770 230 400 50 2 48 1 43 0 55 19 9 71 78 RD 5 18 0 2100 3000 2770 230 400 50 2 48 1 43 0 55 24 9 72 78 RD 6 21 0 2500 3000 2810 230 400 50 3 03 1 76 0 75 25 8 75 81 RD 62 30 0 3000 3000 2850 230 400 50 4 75 2 75 1 3 38 7 78 81 RD 64 35 0 3100 3000 2870 230 400 50 6 65 3 85 1 85 42 3 79 85 RD 65 40 0...

Page 45: ...45 016327 02 18 06 45 Instrukcja obsługi i montażu RD ATEX www elektror pl PL 016327 02 18 06 NOTATKI ...

Page 46: ...46 016327 02 18 06 ...

Page 47: ...47 016327 02 18 06 ...

Page 48: ...ktmanagement unter der Rufnummer 49 0 711 31973 111 zur Verfügung You will find further information about our products on the internet at www elektror com Our Product Management will be pleased to answer your queries at 49 0 711 31973 111 Pour de plus amples informations sur nos produits consulter www elektror fr Notre Management de produits au numéro 49 0 711 31973 111 répondra volontiers à vos q...

Reviews: