2.3.5.1
Connection points
Every cabinet has bus bars on the DC output, which have 3 or 6 connection points on their lower end. Each con
-
nection point can be used to screw one or two cables. The table in section
lists the number and size of the
connection points for every rated output current and power. The connection points as seen from the side:
6x M10 for up to 12 cables
3x M8 for up to 6 cables
Connection example for two cables on one connection point with M10 ring lugs for 150 mm² cables:
The included cover for the DC output bars must always be installed when operating the cabi
-