© EA Elektro-Automatik in 2022, this information is subject to change without notice
47
06230820_manual_psi_10000_3u_15kw_en_01
Group
Parameters & description
Reset / Restart
Reset device to defaults
This touch area will initiate a reset of all settings (HMI, profile etc.) to factory default.
Restart
Triggers a warm start
3.4.3.2
Sub menu “Profiles”
See
“3.9. Loading and saving user profiles“
3.4.3.3
Sub menu “Overview”
This menu page displays an overview of the set values (U, I, P or U, I, P, R), device alarm thresholds, event settings, adjustment
limits, as well as an alarm history which lists the number of device alarms that occurred since the device has been powered.
3.4.3.4
Sub menu “About HW, SW...”
This menu page displays an overview of device relevant data such as serial number, article number etc.
3.4.3.5
Sub menu “Function Generator”
See
“3.10. The function generator“.
3.4.3.6
Sub menu “Communication”
This sub menu offers settings for digital communication via the built-in interfaces USB and Ethernet and also for the optional
interface modules of IF-AB series.
There is furthermore an adjustable communication timeout for USB or RS232, to make it possible to successfully transfer
fragmented messages (data packets) using higher values. In group
Protocols
you can disable one of the two supported com-
munication protocols, ModBus and SCPI. This can help to avoid mixing both protocols and to receive unreadable messages,
for example when expecting an SCPI response and getting a ModBus response instead.
The USB itself doesn’t require any settings. The device will have following default Ethernet port related settings which are
listed in group
Ethernet (internal)
:
IF Settings
Description
Et
he
rne
t (
in
te
rnal
)
DHCP
The IF allows a DHCP server to allocate an IP address, a subnet mask and a gateway. If no DHCP
server is in the network then network parameters will be set as defined below.
IP address
Manually allocate an IP address.
Subnet mask
Manually allocate a subnet mask.
Gateway
Manually allocate a gateway address, if required.
DNS address
Manually allocate addresses of a Domain Name Server (DNS), if required.
Port
Select port in the range 0...65535.
Default port:
5025
Reserved ports: 502 (ModBus TCP), 537
Host name
User definable host name
Domain
User definable domain
S
ettings for the optional interface modules (IF-AB-xxx)
IF Settings
Description
CA
N
op
en
Baud Rate
CAN bus baud rate selection that is used by the CANopen interface.
Auto
= Automatic detection
LSS
= Baud rate and node address are assigned by the bus master
Fixed baud rates:
10 kbps
,
20 kbps
,
50 kbps
,
100 kbps
,
125 kbps
,
250 kbps
,
500 kbps
,
800 kbps
,
1Mbps
Node Address
Selection of the CANopen node address in the range
1
...
127