elektraLite MY 250 User Manual Download Page 10

  9 

The display panel. 

The display panel on 

MY 250

 offers many features. For example, you can set the starting address, switch on 

and off the lamp, run the pre-programmed program or make a reset. 
The Main Menu is accessed by pressing the ENTER button until the display starts flashing which will be about 
3 seconds. You can scroll through the menu using the UP button. Then use the ENTER button again to select 
the menu you want. Confirm every selection by pressing the ENTER button. You can change the selection by 
using the UP button and you can exit a sub-menu by pressing the EXIT button. 
The features of the display panel are listed as follows:- 

 

Default settings shaded. 

 

Main 

menu 

Sub menu 

Extension 

Display 

Function 

VALU 

A001~A511 (AXXX) 

DMX address setting 

SLAV 

ON/OFF     (SLAV) 

Slave setting 

ADDR 

EBOC OFF 

No 

functions 

ALON            (AU-A) 

Automatic Program Run   

in Stand Alone 

AUTO 

MAST            (AU-M) 

Automatic Program Run   

as Master 

ALON            (SO-A) 

Sound-controlled Program 

Run in Stand Alone 

RUN 

SOUN 

MAST            (SO-M) 

Sound-controlled Program 

Run as Master 

VALU 

D–00 ~ D-30   
(DXXX) 

Display the DMX 512 value 

of each channel 

RDIS 

ON/OFF Reverse 

display 

0 MODE 

DISP 

CLDI 

ON/OFF 

Shut off LED display 

OPEN 

ON/OFF  

Lamp 

on/off 

ONLI 

ON/OFF 

 

Lamp on/off via controller 

1 LAMP 

DELA 

D–00 ~ D-59,D-15 

 

Delay lamp on 

RPAN 

ON/OFF  

Pan 

Reverse 

RTIL 

ON/OFF  

Tilt 

Reverse 

16BI 

ON/OFF 

 

Switch 16 bit/8 bit 

REST 

ON/OFF  

Reset 

LODA 

ON/OFF 

 

Restore factory settings 

2 SET 

VER 

V-1.0~V-9.9  

Software 

version 

LADJ 

ON/OFF  

Lamp 

adjustment 

3 ADJU 

TEST 

T–01 ~ T–30 

 

Test function of each channel 

MATI 

0000~9999 (hours)   

Fixture running time 

LATI 

0000~9999 (hours)   

Lamp running time 

CLMT 

ON/OFF 

 

Clear fixture time 

4 TIME 

CLLT 

ON/OFF 

 

Clear lamp time 

STEP 

S–01 ~ S–48 

 

Steps of Program Run 

C–01 ~ C–30 

01XX (00~FFH) 
30XX (00~FFH) 

Edit the channels of each 

scene 

TIME (sec.) 

T – – X (1~9) 

Time for each scene 

5 EDIT 

SC01 

 ~  

SC48 

CNIN 

ON/OFF 

Edit program via controller 

Summary of Contents for MY 250

Page 1: ...MY 250 USER MANUAL V1 12 Elektralite is a division of Group One 70 Sea Lane Farmingdale NY 11735 USA Tel 1 516 249 3662 Fax 1 516 249 8870 WWW MYELEKTRALITE COM...

Page 2: ...ed Saved Program You can edit and save a program internally in the fixture by using either the display panel of the fixture or using an external controller your Elektralite CP10xt or CP20xt You can sa...

Page 3: ...up The lamp produces a considerable amount of heat and as a result the housing does get hot You can be burnt if you touch it Never look directly into the lamp source Sensitive person could suffer an e...

Page 4: ...h In engineering drawings 10mm is also written or described as M10 1 5mm is the distance between each thread or turn of the screw Engineering drawings refer to this as the pitch of the screw Now in pl...

Page 5: ...xplode Only turn on the fixture with the lamp securely inside the fixture and the cover plate screwed on B Mounting MY 250 Method 1 Installation using a C clamp The installation must always be secured...

Page 6: ...y 0 4 of an inch In engineering drawings 10mm is also written or described as M10 1 5mm is the distance between each thread or turn of the screw Engineering drawings refer to this as the pitch of the...

Page 7: ...Y 250 and remember don t clamp the safety to the same half cheeseboros or C clamp That defeats the reason for a safety cable namely a SEPARATE backup to the primary hanging mechanism DMX 512 control c...

Page 8: ...connector at the very end of the DMX cable run In other words at the last MY 250 It maybe the case that you will need to connect a 5 pin XLR to the 3 pin XLR In a normal DMX wiring configuration the...

Page 9: ...if we start with the first MY 250 its first channel is 1 So we refer to it as having a starter address of 1 The second MY 250 will then have its first channel or starter address at channel 17 The thir...

Page 10: ...Program Run in Stand Alone AUTO MAST AU M Automatic Program Run as Master ALON SO A Sound controlled Program Run in Stand Alone RUN SOUN MAST SO M Sound controlled Program Run as Master VALU D 00 D 3...

Page 11: ...EXIT DN to return to main menu Slave setting This function turns MY 250 into a slave 1 Select SLAV by pressing UP button 2 Press ENTER the display shows ON or OFF 3 Press UP to select ON to enable thi...

Page 12: ...nnel If you select D 14 the display will only show the DMX value of the 14th channel 4 Press ENTER to confirm 5 The display shows D XX X stands for the DMX value of the selected channel 6 Press ENTER...

Page 13: ...o select ON if you wish to enable this function or OFF if you don t 4 Press ENTER to confirm 5 Press EXIT DN to return to the main menu Delay lamp on This function delays the lamp ignition 1 Select DE...

Page 14: ...tion or OFF if you don t 4 Press ENTER or EXIT DN to exit Restore factory settings This function restores the factory settings of the device All settings will be reset to the default values shaded Any...

Page 15: ...e main menu display flashing 2 Press UP to select TIME Fixture running time This function displays the running time of MY 250 1 Select MATI by pressing UP button 2 Press ENTER the display shows XXXX X...

Page 16: ...C 01 it means you are editing channel 1 of the selected scene 5 Select the channel number you would like to edit by pressing UP 6 Press ENTER to enter editing for the selected channel the fixture rea...

Page 17: ...splay shows OFF 6 Press UP the display shows ON 7 Press ENTER the display shows SC02 You successfully downloaded the first scene 8 Adjust the Step time as described above under point 12 9 Call up the...

Page 18: ...cle gobo shake CHANNEL 5 pan movement max 630 CHANNEL 6 tilt movement max 265 CHANNEL 7 speed pan tilt movement blackout selection CHANNEL 8 select prism or normal lens prism rotation and speed Also 1...

Page 19: ...rotation 194 255 Backwards rainbow effect from slow to fast Channel 2 Rotating gobos 0 9 Open 10 19 Rot gobo 1 20 29 Rot gobo 2 30 39 Rot gobo 3 40 49 Rot gobo 4 50 59 Rot gobo 5 60 69 Rot gobo 6 70...

Page 20: ...2 127 Gobo 1 shake slow to fast 128 143 Gobo 2 shake slow to fast 144 159 Gobo 3 shake slow to fast 160 175 Gobo 4 shake slow to fast 176 191 Gobo 5 shake slow to fast 192 207 Gobo 6 shake slow to fas...

Page 21: ...07 Macro 10 208 215 Macro 11 216 223 Macro 12 224 231 Macro 13 232 239 Macro 14 240 247 Macro 15 248 255 Macro 16 Channel 9 Focus 0 255 Continuous adjustment from far to near Channel 10 Shutter strobe...

Page 22: ...missing or the stepper motor is defective or it could be the drive circuit on the main circuit board Normally after a reset the color wheel will go to its default position 02Er Rotating gobo wheel er...

Page 23: ...stick or squeak 3 Regularly look for wear and tear on the 120 volt input cable and the DMX signal cable 4 Clean MY 250 at frequent intervals Use a moist lint free cloth Do not use a wet cloth or a cl...

Page 24: ...23 Other Elektralite Products include Also check out our website at www myelektralite com CP 3 Controller CP 10xt Controller CP 16 24 Controller...

Page 25: ...24 CP 20xt Controller TurboFog Fog Machine...