background image

 

1.      GENERAL DESCRIPTION 

 

ThruScan

 WTMD’s are all easy to operate, advanced microprocessor controlled, with digital pulse 

induction  utilizing  VLF  Technology  that  provides  superior  metal  discrimination  and  detection. 

ThruScan  sX/sXWP/s15-i/sX-i  are  versatile and  easily  portable  walk-through metal detection units 

providing  high  level  of  detection  with  a  walk-thru  rate  of  up  to  60  persons  per  minute.  (*  for 

ThruScan

 s3/s6 approx. 30 persons/min) 

 

 

ThruScan

 s15-i/sX-i have fifteen / nine stable and homogeneous detection fields that comprise of 

several  horizontal  and  vertical  zones,  which  can  detect  metal  objects  within  separate  scanning 

zones  of  the  WTMD.  With  widened,  stable  and  homogeneous  detection  zones,  the  WTMD 

determines the search locations for the target objects and displays them on the side panels with 

LED  lights  and  on  the  LCD  display  graphically,  thus  speeds  up  the  walk  through  process 

substantially. The operator needs to search only the indicated areas by 

ThruScan

’s s9/sX/sX-i/sX-

WP on the side panels. See Section 3.4 

 

A bright, highly visible LED VU display provides a visual indication of the level of detection of metals 

within  the  field  of  detection.  Operator  may  also  approximate  the  magnitude  of  the  metal  by  the 

warning sound without looking the 

ThruScan

’s VU-meter on the Control Panel. 

 

Traffic  LED’s  (Green  or  Red)  on  the  side  panels  (ENTER  SIDE)  show  if  WTMD  is  ready  to  pass 

through. If the lights show green the gateway may be entered, if the lights show red the person 

must not enter. See Section 3.3 

(*for

 

ThruScan

 

s3/s6 traffic lights are under the Control 

Panel at gateway)

 

 

Zone lights show the location of the metal object whether it is on the left, right, top, bottom or at 

the centre of the body  and are located on the  side panels of the exit side of the gateway. Zone 

lights originate from LED arrays of 2x6 to show 9 zones. These zones are being indicated on the 

control panel also by “Graphic Zone LEDs (Locator)”.

 

(*for s3/s6 models, display is only at the 

control panel)

 

 

 

A  backlit  LCD  Display  (monitor),  (See  Program  MENU  Section  3.1.1)  is  located  on  the  overhead 

Control Unit and displays operational information including program, alarm and sensitivity settings 

as well as a traffic count of both in-coming and out-going passes. 

 

A see through cover with mechanical lock 

(* optional for

 

ThruScan

 s3/s6)

 enables access to the 

Control Unit in order to prevent unauthorized tampering. Calibration and control settings are further 
protected by a Programmable 4 digit 

PIN CODE

. See Section 6.8 

 

ThruScan

  (s9/sX/s15-i/sX-i/sX-WP)  also  incorporates  an  integral  UPS  battery  backup 

(*optional 

for 

ThruScan

  s3/s6) 

supply  to  protect  the  WTMD  from  power  fluctuations  and  to  maintain 

operation  for  up  to  2  hours  (longer  times  optional)  in  case  of  mains  failure.  The  WTMD 

automatically shuts itself down in case of lack of required voltage. 

Another unique feature of the 

ThruScan

  sX/sX-i/sX-WP

 

  is its ability to monitor up to 99 separate 

(* for 

ThruScan

 s3/s6/s9  sixteen WTMDs for 1 PC)

 

ThruScan

 

 

 units remotely from a PC or 

even  remotely  from  anywhere  in  the  world  via  a  standard  and  satellite(thuraya)  telephone  lines 

under a modem connection. The hardware for this feature is built in as a standard and the SCADA 

software and connection cables are available separately as an option. See Section 7.1 

Other features of the 

ThruScan

 

 

 include superior sensitivity, stability and silent operation ability. 

All electronic components are built into the overhead Control Unit. Connection with the side panels 

are  done  with  sockets,  reducing  problems  often  associated  with  cable-connected  console  and 

simplifying required intervention in case of a breakdown.  

 

Summary of Contents for ThruScan s15-i

Page 1: ...Manual www elektral com tr MAIN CONTACT FACTORY Ataturk Industrial Zone M K Ataturk Blv 23 Cigli 35620 Izmir TURKEY Phones 90 0 232 376 7300 Fax 90 0 232 376 7030 e mail elektral elektral com tr Vers...

Page 2: ...PLAY PANEL INDICATION INFORMATION 18 3 1 Control Panel 18 3 1 1 LCD Display 18 3 1 2 Grafic Alarm Zone LEDs Locater 18 3 1 3 VU Display LED Array 19 3 1 4 UPS Indicator 19 3 1 5 IRDA Remote Control Re...

Page 3: ...SCADA Address 34 4 1 21 Panel Visibility 34 4 1 22 SCD Statistics 34 4 1 23 Statistics Menu 35 5 SYSTEM OPERATION 35 5 1 Normal Operating Mode 35 5 2 Routine Tests 35 5 3 Alarm State 36 6 TECHNICAL S...

Page 4: ...2 Installation Problems 51 9 3 Operational Problems 53 10 APPENDIX 55 10 1 Certificate of Expertise 55 10 2 SRC SCADA Remote Control 55 10 2 1 ThruScan s3 s6 s9 SRC SCADA Program Manual 55 10 2 2 Thru...

Page 5: ...rket companies with credible references ThruScan will earn your approval with quality service guarantee and economic prices Thank you for selecting a product manufactured by ELEKTRAL A S We hope to ea...

Page 6: ...mbol inside the equilateral triangle informs the user that in the context of the product there is enough amount of uninsulated dangerous voltage to cause an electric shock DO NOT OPEN ThruScan ELECTRO...

Page 7: ...d both by a mechanical lock and an electronic PIN CODE as a precaution against unauthorized people Do not share your password Contact the factory if you forget the password Assemble your ThruScan on a...

Page 8: ...women as well as magnetic media A report of expertise on this issue is presented in Appendix 1 See Section 10 1 Protect your ThruScan from direct rain mist and or condensation and place it on a stabl...

Page 9: ...and are located on the side panels of the exit side of the gateway Zone lights originate from LED arrays of 2x6 to show 9 zones These zones are being indicated on the control panel also by Graphic Zon...

Page 10: ...0 different and 10 level adjustable warning tones Alarm Counter In Counter one way at 5 Digits Visible Invisible 4 Digit changeable PIN CODE Automatic Failure Display Reloading the Factory Default Set...

Page 11: ...Alarm counter 5 Digit Incoming counter Visible invisible 4 Digit changeable digital PIN CODE Automatic Failure Display Reloading the factory default settings by one touch button Easy programming and m...

Page 12: ...evel green yellow red VU meter Environmental Magnetic Noise Level Display 10 different and 10 level adjustable warning tones Alarm Counter In Outgoing Counters separately at 5 Digits Visible Invisible...

Page 13: ...ty for a specific weapon or test object fast consistent calibration SMART DETECTOR Graphic Zone Display Display of Metal Density at 10 level green yellow red VU meter Environment Magnetic Noise Level...

Page 14: ...specific weapon or test object fast consistent calibration SMART DETECTOR Graphic Zone Display Display of Metal Density at 10 level green yellow red VU meter Environment Magnetic Noise Level Detectio...

Page 15: ...oing Counters separately at 5 Digits Visible Invisible Mechanical Lock For Control Panel and 4 Digit changeable PIN CODE Automatic Failure Error Code Display Adjustable Alarm Duration 0 5s 2s IR Prote...

Page 16: ...10 tones level or Soundless Mute operation Record Statistics of Operation Duration Number of Visitors and Alarms Real Random Alarms Separately Five Digit IN OUT Traffic Counters Visible Invisible Mech...

Page 17: ...an sX WP is produced for outdoor fulfilling IP55 standards To avoid external metal interference ensure that there are no large metal items near ThruScan False alarms may be caused by nearby moving met...

Page 18: ...ontrol Unit using the three small fixing screws previously removed see 2 2 4 above 2 2 8 Attach the back fixing crosspiece using the remaining four panel fixing bolts only ThruScan s3 s6 s9 do not ful...

Page 19: ...d on the display panel 3 1 1 LCD LIQUID CRYSTAL DISPLAY SCREEN The LCD is an ongoing visual display located in the overhead Control Unit The LCD displays the security level settings and traffic count...

Page 20: ...5 IRDA REMOTE CONTROL RECEIVER only for ThruScan sX s15 i sX i It is the receiving LED of the pilot Remote Control Unit 3 1 6 TRAFFIC INDICATOR LEDS LIGHTS The Traffic Light simulation on Side Panels...

Page 21: ...nt the detected metal objects throughout the WTMD Passage ThruScan s3 s6 models do not have this feature but they do have Graphic Zone LED s on the control panel WARNING In case of a power cut ThruSca...

Page 22: ...ovides the control and use of peripheral equipment such as CCTV Camera Turnstiles Gates etc These contacts RJ11 12 can be used for 24 VDC 2 Amps 1 NO Normally Open 2 NO Normally Open 3 Common 4 Common...

Page 23: ...he 2nd digit of the user code by using the UP DOWN buttons Then press SEL 3 Select the 3rd digit of the user code by using the UP DOWN buttons Then press SEL 4 Select the 4th digit of the user code by...

Page 24: ...ity levels from security level 000 the highest sensitivity to 246 the lowest sensitivity In this very distinctive feature The security Level is defined and assigned by the AD Auto Designation techniqu...

Page 25: ...ity level To change the selected security level proceed with the following 2 Press the SEL button once The display will change to show the current security level number e g Level 3 ThruScan s3 s6 s9 T...

Page 26: ...ruScan sX sX WP are divided into 3 sections bottom zone ZONE 1 middle zone ZONE 2 and top zone ZONE 3 Exclusively the sensitivity level of ThruScan can be adjusted separately in each zone i e the midd...

Page 27: ...cally displayed 5 Use UP DOWN buttons to reach the required tone type 6 Press SEL button to select and fix the setting Press UP DOWN buttons to move to the next sub MENU option or press RUN X button t...

Page 28: ...of the passings are being controlled from screen Counter can be resetted as follows 1 Find COUNTER sub MENU in the MENU by UP DOWN buttons 2 See Counts that are displayed 3 To reset counts press SEL...

Page 29: ...buttons in STATISTICS until the ALARM COUNTER sub MENU option is displayed 7 Counter value stored in the memory will be displayed for both the IN OUT counters separately 8 To reset the counters press...

Page 30: ...Use UP DOWN buttons to select the language English German Turkish or Spanish 4 Press the SEL button to select and fix the setting Press the UP DOWN button to move to the next sub MENU option or press...

Page 31: ...he next sub MENU option or press RUN X button to store the changes and thus return to the normal operating mode 4 1 11 ENVIRONMENTAL NOISE This MENU is prepared to measure the electromagnetic noise le...

Page 32: ...When the value is increased the alarm duration decreases To adjust this period 1 Press UP DOWN buttons to find ALARM DURATION sub MENU 2 Enter to MENU by SEL buton 3 Select your alternatif by UP DOWN...

Page 33: ...is to Display the Percentage of Alarms generated by ThruScan Percentage of Alarms is the ratio of Alarms and Persons Passing through the WTMD Alarm Rate Persons Pass Through WTMD Alarms Generated 1 Pr...

Page 34: ...ontinuously tests its operation and functions and displays the error when an unexpected condition occurs For example ERROR 00 is displayed on the screen when the IR sensors do not see each other for a...

Page 35: ...etting press button SEL Press UP DOWN buttons and change to the next sub MENU option or press RUN X button to store the changes and thus return to the normal operating mode 4 1 22 SCD STATISTICS Only...

Page 36: ...oise Pacing is performed when Green READY pacing lights are on Operation is realized according to the instructions 5 1 NORMAL OPERATING MODE As stated below operating and using ThruScan is easy Using...

Page 37: ...he day s operation 5 3 ALARM STATE If a person triggers an alarm when passing through the archway the operator should instruct the individual to step outside the walk through and remove any metal obje...

Page 38: ...etection for a prolonged period Error 04 Left Centre Zone High Metal Detection for a prolonged period Error 06 Right Centre Zone High Metal Detection for a prolonged period Error 07 Left Bottom Zone H...

Page 39: ...anical lock And thus it protects the access to the system controls Changes to the set up program MENUs are further protected by a 4 digit PIN CODE changeable for ThruScan s3 s6 mechanical lock is opti...

Page 40: ...e minimised ThruScan sounds an alarm for every area where a metal exists 6 13 SYNCHRONISATION If two or more ThruScan units need to be placed next to one another in tandem multiple operation Operation...

Page 41: ...try enable a high transition of approximately 50 60 persons per minute may vary with the metal magnitude depending on the alarm activation delay for s3 s6 30 40 persons min 6 19 WEIGHT kgs ThruScan s3...

Page 42: ...ntrol Software separate softwares are used for ThruScan sX sX WP s15 i sX i and ThruScan s3 s6 s9 Specially modified Modem and Special Connection Cable Up to 99 ThruScan sX sX WP s15 i sX i units can...

Page 43: ...are ThruScan sX sX WP s15 i sX i SRC SCADA Software 7 1 2 REMOTE CONTROL by MODEM The second accessory of the Remote Control Package is a specially modified modem This modem is not a standard modem It...

Page 44: ...the cable is passed through a hole on the rain shelter after the drilling isolation has to be made on that hole to prevent leakage of water NOTE The drain hole is placed on one side of the rain shelte...

Page 45: ...and the Nut to fix the Camera Assembly bar to the Control Unit Connect the camera socket to the same number connector inside the control unit If you wish to continuously observe images from the system...

Page 46: ...system at View mode 4 External trigger for capture 4 1 Activation depends on which camera is active 4 2 If ch1 is in view if TG1 active capture a photo from ch1 if TG2 active the system will switch to...

Page 47: ...ess OK to select from 1to 9 the bigger figure the longer interval to active the detection Setting n is about n 2 sec between 2 snap shot 7 4 5 Set up motion detect sensitivity use OK to select Hi Mid...

Page 48: ...ivity AVI frame setting AVI duration setting Quit Photo Management Delete one photo Format memory clear all files Delete one photo REMOTE CONTROL BUTTONS Is used to exit from IR control menu Or to go...

Page 49: ...of 4 mm ABS Plastic approx 780 x 500 x 350 mm 80 mm sliding top depth Available with all WTMD Models 7 12 Queue Barrier Chrome plated 90 cm height weights approx 9 kg 2 5 m length and 48 mm thick red...

Page 50: ...d information from our web site www elekral com tr If problems are related with the environment see Section 2 1 or contact your Dealer or our Company for assistance Adjusting or relocating the or remo...

Page 51: ...person or property shall be available to him Service Station Elektral Elektromekanik San Ve Tic A S Izmir Ataturk Industrial Zone M K Ataturk Blv 23 Cigli 35620 Izmir TURKEY Phones 90 0 232 376 7300...

Page 52: ...ng and dismounting procedures in the user s manual would not cause any failure Are there any restrictions for the place of the mounting You should mount your WTMD as in the necessary distance away fro...

Page 53: ...connection You may operate and or make the adjustments of your WTMD from anywhere around the world using a standard telephone line as cable or satellite connection GSM or THURAYA The accessory necessa...

Page 54: ...up to 100 meters 9 3 OPERATIONAL PROBLEMS Does keeping the WTMD without operating for a long time require any adjustment or maintenance Storing in suitable conditions or keeping without operation does...

Page 55: ...WTMDs operating side by side There should be a distance of 30 cms at least between two operating WTMDs Read your manual first before operating two or more WTMDs side by side See Section 6 13 I want t...

Page 56: ...button In Section 10 2 1 you may see the ThruScan s3 s6 s9 SRC SCADA Software and in Section 10 2 2 ThruScan sX sX WP s15 i sX i SRC SCADA Software user manuals 10 2 1 ThruScan s3 s6 s9 SRC SCADA Remo...

Page 57: ...t limitation any implied warranties of merchantability or fitness for a particular purpose Use under your own responsibility but comments even critique in English German or in Turkish are welcome 10 2...

Page 58: ...ss 1 12 Select Real Time from the Options at the bottom of the SCADA screen in order to observe the detection counting audible visible alerts instantly Select from Options 1 to 5 to set the alarms dur...

Page 59: ...he transportation accessory and then the item number h should be used to fix the accessory by screwing to the bottom part of the side panels Make sure that you are not screwing extremely tight NOT TO...

Page 60: ...rough item number e the wheels to be fixed at both ends of item number c as shown on the Figure 1 and Figure 2 5 Item number g should be fixed at both ends To disassemble the steps described above sho...

Page 61: ...rized to confirm above mentioned particulars all price and costs are FOB Izmir TR All the transport or travel costs are bared by the buyer 4 ELEKTRAL is not to be labelled for loss of other damage all...

Reviews: