Electrostatic Technology, Inc.
Trickle Impregnation System
Serial #18028
13
5 AIR AND ELECTRICAL REQUIREMENTS
5.1
TRICKLE IMPREGNATION MACHINE
5.1.1 Air
A clean, oil free, dry supply of compressed air must be provided using 1 inch
I.D. line capable of supplying 50 scfm @ 80 psi minimum to 100 psi maximum.
5.1.2 Electrical
480 Volts, 60 Hertz, 3-Phase, 100 Amp service Plant Power must be supplied to
the Main Disconnect on the rear of the machine.
5.2 INDUCTION
HEATER
5.2.1 Electrical
Power for the Induction Heaters is supplied from the main power input specified
in Section 6.1.2 above.
5.2.2 Water
5.2.2.1
Closed Loop Induction Heater Cooling System
Distilled water is required for the Closed Loop Induction Heater
Cooling System. Approximately 10 gallons of distilled water is
required to fill the system.
5.2.2.2
Tower Water Requirements for Induction Heater Cooling
Customer must supply 7.5 gallons/minute at 30 psi of cooling water
(85º F
maximum, 45º F minimum) to the Heat Exchanger for the
Closed Loop Induction Heater Cooling System.
5.3
FIRE EXTINGUISHER SYSTEM
5.3.1 Electrical
110 Volts, 60 Hertz, 1-Phase, Plant Power must be supplied to the Fire
Extinguisher System Control Unit.