-11-
Setting with a Keyfob
To set the system using a keyfob:
•
Press the relevant button on your keyfob (
see 2.3: Keyfobs
); the exit delay
begins to count down. At the end of the exit delay, the system is armed.
Forced Setting
Forced setting enables you to set when the system is not ready. For example, if a door
protected by a magnetic contact is open, you may set the system on condition that the
door will be closed by the end of the Exit delay. If the door is still open after the exit
delay expires, an alarm is generated.
Forced setting is available only if the option is enabled in programming. Forced setting
may be enabled for specific zones or for the entire system.
Instant Setting
Instant setting is a feature that allows you to cancel the entry delay after Part or
Perimeter setting the system. For this feature to function, it must be enabled in
programming by your engineer.
To instantly set the system.
1. Check if the system is ready to set.
2. Press the Part or Perimeter setting key on the keypad and enter your user code
if One-Key Setting is disabled.
3. Press and hold down
on your keypad until the message
Instant Setting, OK?
is displayed.
4. Press √; the entry delay for the current setting period is canceled.
Supervised Set
Supervised Set is an optional feature designed to supervise intrusion sensor activity
before you set the system.
If Supervised set is enabled in programming and the system has not received a
transmission from a sensor for a certain amount of time, all setting methods that include
that sensor shall not be available.
In this case, press
to check which sensor is causing the “System Not Ready” condition.
To make the required setting method available, activate the sensor. If activating the sensor
does not help, there may be a problem with the sensor. You can omit the faulty sensor’s
zone to allow system setting until the problem is remedied –
see 7.2: Zone
Bypassing/Unbypassing.
3.2: Unsetting the System
When you enter the premises, the entry delay begins
to count down. You must unset the system within the
entry delay time to prevent the system from triggering
an alarm.
To unset the system using a keypad:
•
Enter your user code.
To unset the system using a keyfob:
•
Press the unset button –
see 2.3: Keyfobs
.