89
Anomaly
Type of
anomaly
Description
Possible
causes
Instructions to User
Action for Service*
N°290
EntC
Stops
machine.
Component
compartment
NTC failure
(NCC).
- Connector
failure.
- TC sensor
failure.
- ACU failure.
Electronic board temper-
ature sensor damaged.
Cooking impossible.
Check NTC signal (see “Compo-
nents compartment (NCC)“
section in “Detailed appliance
and components description/
functioning“ chapter of the proper
Service manual).
Check X40 on ACU (see “Power
board (ACU)“ section in “Detailed
appliance and components
description/functioning“ chapter
of the proper Service manual).
Replace NCC (see “Components
compartment (NCC)“ section in
“Detailed appliance and compo-
nents description/functioning“
chapter of the proper Service
manual).
N°251
Eotd
Warning
High tempera-
ture on drain
(NM8).
Possible lack of
water in the
drain system.
High temperature on
drain; Check that the
oven has water supply;
Pour some fresh water
on the bottom cavity filter
pay attention, do not
splash hot cavity with
cold water because it
could damage the
machine.
If the problem persists,
call Service.
Cool down NM8, pour some
water on the bottom cavity filter.
Activation at 100
℃
.
N°320
Epr1
Stops only
food probe
cycles.
Single point
core probe
failure.
- Food probe
misuse (for
example, wire
pulled or
squeezed).
- Connector
failure.
- Probe failure.
- ACU failure.
It is possible to run
cycles based on time
(without food probe). If
available, use the acces-
sory USB food probe.
For restoring full func-
tionality, call Service.
Check X15, X16 and X17 on ACU
(see “Power board (ACU)“ sec-
tion in “Detailed appliance and
components description/function-
ing“ chapter of the proper Service
manual).
Check food probe (see “Food
probe TFP“ section in “Detailed
appliance and components
description/functioning“ chapter
of the proper Service manual).
Replace food probe (see “Food
probe“ section in “Servicing the
appliance“ chapter of the proper
Service manual).
N°321
Epr6
Stops only
food probe
cycles.
Six points core
probe failure.
- Food probe
misuse (for
example, wire
pulled or
squeezed).
- Connector
failure.
- Probe failure.
- ACU failure.
It is possible to run
cycles based on time
(without food probe). If
available, use the acces-
sory USB food probe.
For restoring full func-
tionality, call Service.
Check X15, X16 and X17 on ACU
(see “Power board (ACU)“ sec-
tion in “Detailed appliance and
components description/function-
ing“ chapter of the proper Service
manual).
Check food probe (see “Food
probe TFP“ section in “Detailed
appliance and components
description/functioning“ chapter
of the proper Service manual).
Replace food probe Replace food
probe (see “Food probe“ section
in “Servicing the appliance“ chap-
ter of the proper Service manual).
N°1
Ertc
-
Failure on RTC.
Issue with soft-
ware or hard-
ware (for exam-
ple battery clock
exhausted).
Problem with internal
clock, It is possible that
some functionality do not
work (for example
HCCP).
For restoring full func-
tionality, call service
Check battery BT1 on user board
(U.I) D.3
Summary of Contents for MAGISTAR OVEN 6-10-20GN
Page 16: ...16 C 5 Equipment modules and interactions ...
Page 46: ...46 PRESS and HOLD on PNC field PRESS and HOLD on PNC field 2 3 4 5 6 7 ...
Page 57: ...57 D 4 2 6 HACCP log HACP LOG Once entered into the dedicated Service area scroll until ...
Page 59: ...59 D 4 2 8 Alarm log ALrM LOG Once entered into the dedicated Service area scroll until ...
Page 123: ......
Page 124: ...Electrolux Professional SPA Viale Treviso 15 33170 Pordenone www electroluxprofessional com ...