44
D.3.3.6 PNC and SERIAL number writing in the identity card
This procedure is requested when replacing a spare part UI (User interface); the PNC-SER D.3.1.4
is not written
into replacement/spare part boards and this info is needed for
SKY DUO/CONNECTIVITY
.
In case that we have to replace an
user board UI
it will be necessary to upload into the new board the Programming file,
Programming Parameters files (refer to previous chapters) and also write the PNC and Serial number.
From software version “4.4.12“ the identity card is editable in regards of PNC and Serial number fields. To access in editable mode,
it is necessary to log in as Service, with service password.
In the picture above an example of identity card of a new spare part U.I installed. After
P.P
and
P.F.
upload, the
PNC and SER
will
have not updated and will
result empty
!!
Further info regarding the UI board, refer to user interface D.3
ACU-X27
C1.1 C1.2
O/I BUTTON “SM”
RECOVERY
ACU-X28
USB - J15 OF
USER BOARD (U.I)
DISPLAY
BOARD
USER
BOARD (U.I)
O/I ON OFF
BOARD (SM)
Summary of Contents for MAGISTAR OVEN 6-10-20GN
Page 16: ...16 C 5 Equipment modules and interactions ...
Page 46: ...46 PRESS and HOLD on PNC field PRESS and HOLD on PNC field 2 3 4 5 6 7 ...
Page 57: ...57 D 4 2 6 HACCP log HACP LOG Once entered into the dedicated Service area scroll until ...
Page 59: ...59 D 4 2 8 Alarm log ALrM LOG Once entered into the dedicated Service area scroll until ...
Page 123: ......