Parameters list chart for all level (T, K, B, C)
The visible parameter list is enclosed in this Service manual chapter, but the complete list is made up of over 440 different
parameters, many of these hidden parameters are “special“ and cannot be manually adjusted by the technicians. The only way to
set all parameters is to follow the procedures of the different electronic boards (PP uploading).
The following list refers to the visible parameters for
Touch T, K / Digit B, C
electronic boards. The presence of No. 1 in the Touch /
Digit columns means that parameter is present in those electronics, the presence of “0“ (zero) means that parameter will not be
present.
EXAMPLE:
22 FFSC
has the numbering 1 only in the “Touch column“, this means that the parameter 22 will be present only in the
Touch electronic board while in the Digit electronics it will not be displayed/present.
This list can be used as a reference
for all models
/ electronic boards.
T
ouch
Digit
Parameter
ID
Mnemonic
Short Description
T
able
Min
Max
Default
1
1
1
GAS
Appliance type
{0, “Electric“}
{1, “Gas“}
0
1
0
1
1
3
FAhr
Temperature Scale
{0, “
℃
“}
{1,“
℉
“}
0
1
0
1
1
5
rod
Cooking with open door
{0, “Disabled“}
{1, “Enabled“}
0
1
0
1
1
6
LAMb
Lambda Probe
{0, “Disabled“}
{1, “Enabled“}
0
1
1
1
1
7
FCLn
Cleaning environment (factory
setting)
{0, “Disabled“}
{1, “Enabled“}
0
1
1
1
1
9
PPM
Power Peak Management
{0, “Disabled“}
{1, “Enabled“}
0
1
0
1
1
10
dEMo
Demo Mode
{0, “Disabled“}
{1, “Event mode“}
{2, “Portable“}
0
2
0
1
1
12
Phbo
Preheat the boiler in stop
mode
{0, “Disabled“}
{1, “Enabled“}
0
1
0
1
1
13
FMAn
Manual mode (factory setting)
{0, “Disabled“}
{1, “Enabled“}
0
1
1
1
1
14
PrEh
Cavity preheating
{0, “Disabled“}
{1, “Enabled“}
0
1
1
1
0
15
Faut
Automatic mode (factory
setting)
{0, “Disabled“}
{1, “Enabled“}
0
1
1
1
0
22
FFSC
Food Safe Control (factory
setting)
{0, “Disabled“}
{1, “Enabled“}
0
1
1
1
1
24
APPL
Appliance level
{0, “Combi“}
{1, “Convection“}
0
1
0
1
1
25
APPM
Appliance model
{0, “LW 6 1/1“}
{1, “LW 6 2/1“}
{2, “LW 10 1/1“}
{3, “LW 10 2/1“}
{4, “LW 20 1/1“}
{5, “LW 20 2/1“}
0
5
0
1
1
26
bPHt
Boiler preheating temperature
0
99
97
1
1
30
SEAL
Height above the sea level
0
4000
0
1
1
31
tHMA
Maximum temperature for
manual water injection
180
300
220
1
1
32
trMA
Maximum temperature to use
water in cool down
150
300
180
1
1
33
trMn
Minimum temperature to use
water in cool down
0
180
30
1
1
38
ArEC
Advanced recovery mode
{0, “Disabled“}
{1, “Enabled“}
0
1
1
1
0
39
grEn
Green Options (factory
settings)
{0, “Disabled“}
{1, “Enabled“}
0
1
1
1
1
44
CLnd
Default cleaning cycle
{0, “Extra Strong“}
{1, “Strong“}
{2, “Medium“}
{3, “Soft“}
{4, “Rinse“}
0
4
2
Summary of Contents for MAGISTAR OVEN 6-10-20GN
Page 16: ...16 C 5 Equipment modules and interactions ...
Page 46: ...46 PRESS and HOLD on PNC field PRESS and HOLD on PNC field 2 3 4 5 6 7 ...
Page 57: ...57 D 4 2 6 HACCP log HACP LOG Once entered into the dedicated Service area scroll until ...
Page 59: ...59 D 4 2 8 Alarm log ALrM LOG Once entered into the dedicated Service area scroll until ...
Page 123: ......
Page 124: ...Electrolux Professional SPA Viale Treviso 15 33170 Pordenone www electroluxprofessional com ...