102
Anomaly
Type of
anomaly
Description
Possible
causes
Instructions to User
Action for Service*
N°120
PUSr
The User
parameters cal-
culated MD5 is
different to the
stored one.
Invalid data on User
parameters.
Reload parameters.
N°121
PFAC
Stops
machine.
Memorized
parameters
corrupted.
Issue with the
SW or with the
HW.
Parameters memory cor-
rupted; Try to switch the
oven Off/On.
If the problem persists,
call Service.
Reload parameters.
N°111
rtc1
Warning:
HACCP
will not
function.
The communi-
cation channel
between the
RTC and the
microcontroller
is malfunction-
ing or blocked.
Communication impossi-
ble with internal clock.
Call Service.
Replace UI.
N°306
SbbU
-
Boiler 1 burner
fan does not
reach set
(VTBU).
Burner fan does
not reach
desired speed.
Burner blower motor
overload due to dirt or
oxidation; Other electrical
/ mechanical issue.
N°305
SbCd
-
Cavity down
burner fan does
not reach set
(VTCD).
Burner fan does
not reach
desired speed.
Burner blower motor
overload due to dirt or
oxidation; Other electrical
/ mechanical issue.
N°304
SbCU
-
Cavity Up
burner fan does
not reach set
(VTCU).
Burner fan does
not reach
desired speed.
Burner blower motor
overload due to dirt or
oxidation; Other electrical
/ mechanical issue.
N°107
SCbL
Stops
cleaning.
Appliance is ON
but ON/OFF
switch feedback
still OFF.
- Wiring-Con-
nection loose.
Appliance is ON but ON/
OFF switch feedback still
OFF. Power fail feature
not possible. Cooking
still possible. Cleaning
blocked for safety reason.
Try to switch OFF/ON: if
the alarm persists, it is
still possible to operate
cooking, but it is recom-
mended not to start any
cleaning cycle until the
Service will have
resolved the issue. Clean
manually the oven and
call Service.
Check feedback wiring from ON/
OFF switch board to UI board.
N°226
SLUS
Stops
cycle (if
the boiler
is used in
the phase
in execu-
tion).
Boiler water
level under
safety for more
than X min (SL).
Ensure the
water supply
mains are fully
open and the
water filter has
no obstructions
(clean it if
needed). The
oven can con-
tinue to work in
Convection
mode unless the
water is missing
from the mains,
the oven can
continue to work
in recovery
mode.
Water supply valve
closed or partly closed;
Temporary lack of water
supply pressure; Boiler
water level sensor fail-
ure; Boiler leakage: drain
valve or fracture.
Open water supply.
Clean mesh filter on water hose.
Check X25 on ACU (see “Power
board (ACU)“ section in “Detailed
appliance and components
description/functioning“ chapter
of the proper Service manual).
Descale boiler.
For level Touch D.3
.
For level B (Digit) D.4
N°117
tCMS
Blocks
machine;
fatal error.
TC software
version (inside
ACU board)
incompatible
with present UI
SW version.
Wrong software
upload (exam-
ple: after
replacing ACU
board).
TC software version
(inside ACU board)
incompatible with present
UI SW version.
Call Service.
Reload software
Summary of Contents for MAGISTAR OVEN 6-10-20GN
Page 16: ...16 C 5 Equipment modules and interactions ...
Page 46: ...46 PRESS and HOLD on PNC field PRESS and HOLD on PNC field 2 3 4 5 6 7 ...
Page 57: ...57 D 4 2 6 HACCP log HACP LOG Once entered into the dedicated Service area scroll until ...
Page 59: ...59 D 4 2 8 Alarm log ALrM LOG Once entered into the dedicated Service area scroll until ...
Page 123: ......
Page 124: ...Electrolux Professional SPA Viale Treviso 15 33170 Pordenone www electroluxprofessional com ...