ALARM CODES
SSD-P APdV, EB, HD 01/05
8.28
599 34 71-47
NO
NO
NO
Faulty Relay that gives power to the heating element.
Incongruity between anti-boil switch 2 and status of the relay.
Checks to do:
E66
YES
Unplug the connector W1-W2 and
measure directly on the main board, you
should find an open circuit.
Is it OK?
If there are burn marks on
electronic board, see page 13.1-2
Change/Check the cable and run again
the diagnostic cycle to verify any further
possible alarm.
YES
Change the Main board and run again
the diagnostic cycle to verify any further
possible alarm.
Unplug all the connectors from the drying
heating elements and measure directly
between the component and the body of
the machine. Do you measure any
dispersion?
Change the Main board and run again
the diagnostic cycle to verify any further
possible alarm.
Change the drying heating element and
run again the diagnostic cycle to verify
any further possible alarm.
YES
Measure between J2-5 and the body of
the machine. Do you measure any
dispersion?
Summary of Contents for EWM2000
Page 2: ...SSD P APdV EB HD 01 05 II 599 34 71 47 ...
Page 6: ...SSD P APdV EB HD 01 05 VI 599 34 71 47 ...
Page 56: ...BASIC CIRCUIT DIAGRAM SSD P APdV EB HD 01 05 11 1 599 34 71 47 AC MOTOR ...
Page 57: ...BASIC CIRCUIT DIAGRAM SSD P APdV EB HD 01 05 11 2 599 34 71 47 DC MOTOR ...
Page 73: ...SSD P APdV EB HD 01 05 14 10 599 34 71 47 pic 34 pic 35 PICTURES LINKED TO FAULT FINDING ...
Page 74: ...NOTES SSD P APdV EB HD 01 05 14 11 599 34 71 47 ...