ALARM CODES
SSD-P APdV, EB, HD 01/05
8.11
599 34 71-47
Are pressure switch hoses and the air
trap system free?
(you can disconnect the hoses and
blow in them to check if the system is
free )
–
see pic.08,a,b
-
Are pressure switch hoses and the air
trap system free?
(you can disconnect the hoses and
blow in them to check if the system is
free )
–
see pic.08,a,b
-
The sensing of the ”anti-boil switch 1“ on the electronic board is not
working properly
Checks to do:
The sensing of the ”anti-boil switch 2“ on the electronic board is not
working properly
Checks to do:
E36
Clean/change the hoses and/or air
trap system and repeat completely
the diagnostic cycle to verify any
further possible fault
Change the main board and repeat
the diagnostic cycle to verify any
further possible alarm
NO
YES
E37
Clean/change the hoses and/or air
trap system and repeat completely
the diagnostic cycle to verify any
further possible fault
Change the main board and repeat
the diagnostic cycle to verify any
further possible alarm
NO
YES
If there are burn marks on
electronic board, see page 13.1-2
Summary of Contents for EWM2000
Page 2: ...SSD P APdV EB HD 01 05 II 599 34 71 47 ...
Page 6: ...SSD P APdV EB HD 01 05 VI 599 34 71 47 ...
Page 56: ...BASIC CIRCUIT DIAGRAM SSD P APdV EB HD 01 05 11 1 599 34 71 47 AC MOTOR ...
Page 57: ...BASIC CIRCUIT DIAGRAM SSD P APdV EB HD 01 05 11 2 599 34 71 47 DC MOTOR ...
Page 73: ...SSD P APdV EB HD 01 05 14 10 599 34 71 47 pic 34 pic 35 PICTURES LINKED TO FAULT FINDING ...
Page 74: ...NOTES SSD P APdV EB HD 01 05 14 11 599 34 71 47 ...