Empty the machine.
Are pressure switch hoses and the air
trap system free? (you can disconnect
the hoses and blow in them to check if
the system is free ) –
see pic.08,a,b
-
ALARM CODES
SSD-P APdV, EB, HD 01/05
8.10
599 34 71-47
NO
NO
NO
Water level too high
The electronic board measures a water level from analogic pressure switch higher then 300 mm
for more then 15 seconds.
Checks to do:
E35
Clean/change the hoses and/or air trap
system and repeat completely the
diagnostic cycle to verify any further
possible fault.
Change the inlet
valves and
repeat
completely the
diagnostic cycle
to verify any
further possible
alarm.
Get inside
diagnostic cycle
at
step 8
. After
door lock is the
machine also
filling water?
Change the
analogic
pressure switch
and run the
diagnostic cycle
to verify any
further possible
alarm
Is the cable
between main
board and
analogic
pressure switch
connected
correctly on both
sides?
Change the
main board and
repeat
completely the
diagnostic cycle
to verify any
further possible
alarm
Is the machine
filling water
when main
switch is turned
OFF?
Reconnect
and/or replace
the cable and do
the diagnostic
cycle completely
again to verify
any further
possible alarm
code.
NO
YES
YES
YES
If there are burn marks on
electronic board, see page 13.1-2
YES
Summary of Contents for EWM2000
Page 2: ...SSD P APdV EB HD 01 05 II 599 34 71 47 ...
Page 6: ...SSD P APdV EB HD 01 05 VI 599 34 71 47 ...
Page 56: ...BASIC CIRCUIT DIAGRAM SSD P APdV EB HD 01 05 11 1 599 34 71 47 AC MOTOR ...
Page 57: ...BASIC CIRCUIT DIAGRAM SSD P APdV EB HD 01 05 11 2 599 34 71 47 DC MOTOR ...
Page 73: ...SSD P APdV EB HD 01 05 14 10 599 34 71 47 pic 34 pic 35 PICTURES LINKED TO FAULT FINDING ...
Page 74: ...NOTES SSD P APdV EB HD 01 05 14 11 599 34 71 47 ...