ALARM CODES
SSD-P APdV, EB, HD 01/05
8.23
599 34 71-47
NO
NO
The sensing of the component (triac) that commands the Motor
device on the electronic board in not working properly.
Checks to do:
One of the Relays of the main board is not working properly.
Does not exist in the DC version.
Checks to do:
Change the main board and run again the
diagnostic cycle to verify any further possible
alarm
E53
E54
Change the main board and run again
the diagnostic cycle to verify any further
possible alarm
If there are burn marks on
electronic board, see page 13.1-2
Measure between all wires in the
connector J1 in main board and
the
body
of the
machine
(see page 9.1, point “3”).
Do you measure any dispersion?
-
see pic. 20
-
Unplug the connector in the motor and
measure between motor connectors and
body of the machine. Do you see any
dispersion? (-
see pic.21
-)
Replace the Motor and run again the
diagnostic cycle to verify any further
alarm.
YES
YES
Replace/change the cables /wiring and
run again the diagnostic cycle to verify
any further alarm.