![Electrolux EWM2000 Service Manual Download Page 22](http://html.mh-extra.com/html/electrolux/ewm2000/ewm2000_service-manual_100459022.webp)
ALARM CODES
SSD-P APdV, EB, HD 01/05
8.4
599 34 71-47
Is the drain filter clean?
NO
YES
YES
NO
NO
YES
YES
YES
Problems during draining phase
(Machine tries to drain for 10 min without emptying the tub)
Checks to do:
E21
Is the drain
pump working?
(in the diagnostic
cycle select
step
1
filling and then
step 7
- draining)
(noise from the
pump)
Is the value of the
pump about
200
Ω
?
(Measure directly
the connector by
the board,
between J2-2 and
J2-7) -
see pic.04
-
Change the
pump and run
again
diagnostic cycle
to verify any
further possible
alarm
Clean and verify that
pump is working
correctly
Check/Replace
the cable and run
again diagnostic
cycle to verify any
further possible
alarm
NO
Clean the filter and run again the
diagnostic cycle to verify any further
possible alarm
Is the draining system OK (drain hose
and plumbing where machine is
connected)
Free and check the draining system
YES
Is the value of the
pump about
200
Ω
?
(Measure directly
on the pump)
-
see pic.05
-
Is the pump
mechanical
blocked?
Is there any burn
mark on the board in
drain pump area?
(page 13.1-2)
Change the board
and verify if there is
any burn mark
between pump
connectors due to
possible water
leaking
Change the board
and repeat the
diagnostic cycle
completely again and
verify any further
possible alarm
Do the diagnostic
cycle completely
again and verify
any further
possible alarm
code
YES
NO
NO
NO
Summary of Contents for EWM2000
Page 2: ...SSD P APdV EB HD 01 05 II 599 34 71 47 ...
Page 6: ...SSD P APdV EB HD 01 05 VI 599 34 71 47 ...
Page 56: ...BASIC CIRCUIT DIAGRAM SSD P APdV EB HD 01 05 11 1 599 34 71 47 AC MOTOR ...
Page 57: ...BASIC CIRCUIT DIAGRAM SSD P APdV EB HD 01 05 11 2 599 34 71 47 DC MOTOR ...
Page 73: ...SSD P APdV EB HD 01 05 14 10 599 34 71 47 pic 34 pic 35 PICTURES LINKED TO FAULT FINDING ...
Page 74: ...NOTES SSD P APdV EB HD 01 05 14 11 599 34 71 47 ...