Alarm Codes
Service Code
Family
(Platform specific)
Reason
Type
User visible
User
indication
failure
code read
Action in case of failure happens
Dishwashers before
March 2017
User indication
WP BLDC motor not connected
abort
Yes
i58
i58
Cycle will be terminated and electronic switched to reset on-condition
i50
WP BLDC ADC fault
abort
Yes
i59
i59
Cycle will be terminated and electronic switched to reset on-condition
i50
(DIVA2 only)
WP BLDC over temp
stop
Yes
i5A
i5A
Cycle stop and continuous automatically after problem solved – rta off
i50
Please OBSERVE that i5A has different meaning depending on platform
(PB100 only)
WP/DP BLDC overload
abort
Yes
i5A
i5A
Cycle will be terminated and electronic switched to reset on-condition
i50
(PB100 only)
WP/DP current plausibility
abort
Yes
i5b (i5H)
i5b (i5H)
Cycle will be terminated and electronic switched to reset on-condition
i50
(PB100 only)
DP BLDC over current HW
abort
Yes
i5C
i5C
Cycle will be terminated and electronic switched to reset on-condition
i50
(PB100 only)
DP BLDC over current SW
abort
Yes
i5d
i5d
Cycle will be terminated and electronic switched to reset on-condition
i50
(PB100 only)
DP BLDC motor not following
abort
Yes
i5E
i5E
Cycle will be terminated and electronic switched to reset on-condition
i50
(PB100 only)
DP BLDC motor not connected
abort
Yes
i5F
i5F
Cycle will be terminated and electronic switched to reset on-condition
i50
60
Heating problem
warning
No
Nothing
i60
Heating element will be switched off for the rest of the cycle
Nothing
Heating – over temperature
abort
No
i61
i61
Cycle will be terminated and electronic switched to reset on-condition
i60
Heater relay problems
abort
No
i62
i62
Heating element will be switched off for the rest of the cycle
i60
70
NTC problem
warning
No
Nothing
i70
Heating element will be switched off for the rest of the cycle
Nothing
80
Auto Door Opener malfunction
abort
Yes
i80
i80
Cycle will be terminated and electronic switched to reset on-condition
i80
Auto Door Opener timeout
warning
warning
No
Nothing
i81
Auto Door Opener tries to recover. If that fails, the cycle continues
without auto door opener
Nothing
Water Reuse Valve warning
warning
No
Nothing
i82
Cycle continues regardless the error
Nothing
90
Checksum mcf
inactive
No
Nothing
i91
Electronic functionality blocked – all off
Nothing
Checksum ccf
inactive
No
Nothing
i92
Electronic functionality blocked – all off
Nothing
Checksum UIdata
inactive
No
Nothing
i93
Electronic functionality blocked – all off
Nothing
UI data version mismatch
warning
No
Nothing
i94
No update of UI configuration data is possible
Nothing
UI data checksum mismatch
warning
No
Nothing
i95
No update of UI configuration data is possible
Nothing
Technical Support – A.R.
Chapter
4
599 79 76 - 53 REV 1.0