Alarm Codes
•
i82
code: Water Reuse valve warning
•
This warning is set if the Water Reuse valve is detected not opened during
the water tank conditioning, or
•
If the Water Reuse valve is detected not closed in the beginning of the cold
rinse phase in every Elabel or intensive Care cycle.
•
The warning is not displayed, the cycle continues.
•
i90 Code - family : Configuration Problem
•
i91
code: checksum MCF
•
No washing program start is possible, can be resolved by turning the
appliance off and back on again.
•
The display board does not satisfy the identification requests of the main
board.
•
i92
code: checksum CCF
•
The alarm is signalled if the configuration control of the washing cycles
provided erroneous results.
•
i93
code: checksum UIDATA
•
The alarm is signalled if the configuration control of the UI configuration
data provided erroneous results.
•
i94
code: UIDATA version mismatch
•
The alarm is signalled if the UIDATA provided in configuration file
mismatches the attached UI board.
•
i95
code: UIDATA checksum mismatch
•
The alarm is signalled if the UIDATA checksum type provided in
configuration file mismatches with the attached UI board.
•
iB0 (iH0) Code - family : Sensor Problem
Note: “B” may be displayed as “H” in the 7-segment display
This family has different meaning depending on PB and PB firmware
releases.
Past production specific
This range includes the following PBs and PB firmware releases:
-
Diva & Diva2
-
PB100 before P100R230 (Excluding P100R230)
-
PB200
-
PB300
•
iB0 (iH0)
code: turbidity sensor
•
The alarm is set if the calibration procedure is not completed after
15 sec.
•
The washing program will run as though the dirt value to be
considered is high.
Technical Support – A.R.
Chapter
4
599 79 76 - 53 REV 1.0