Alarm Codes
i11
code: during dynamic filling
•
Acoustic signal and visual alarm, depending on the appliance
customization; the program can be restarted.
•
The water level defined is not reached within the time limit set.
•
The time limit set starts when the fill solenoid valve is opened.
•
The time limit set is reset when the fill solenoid valve is closed.
•
The water will first be drained before an error is displayed to the user.
•
Time limit set: Normal 120 sec; Test cycle = 60 sec (times could differ as
they are defined in the washing cycle specifications)
•
i20 Code - family : Draining Problem
•
i20
code : Fails to drain
•
Acoustic signal and visual alarm, depending on the appliance
customization; the program can be restarted.
•
The level switch restore point is not reached within the time limit set.
•
The time limit set starts when the drain pump is activated.
•
The time limit set is reset when the drain pump stops normally.
•
Time limit set: Normal 90 sec; Test cycle = 60 sec
•
i30 Codes - family : Aqua Control
•
i30
code: aqua control error detected
•
The error is set if there is water detected in the bottom tray, or the drain
pump is disconnected or the winding in the pump is open circuit.
•
Acoustic signal and visual alarm, depending on the appliance
customization; the program is restarted automatically in this alarm
condition.
•
If this alarm condition occurs, the drain pump is activated.
•
Time limit set: 10 sec.
•
i40 Codes - family : Analogue pressure sensor
problem
•
i41
code: No pressure sensor signal
•
The error is set if the sensor signal is lost for more than 2,5s.
•
Abort program and display error.
•
i42
code: Calibration invalid, pressure signal too noisy
•
The warning is set if the sensor signal is not stable enough for calibration
or if the signal is out of range for an empty sump.
•
The signal noise level for calibration is defined in MCF.
•
i43
code: Pressure sensor signal too high
•
The error is set if the sensor signal is out of range, signal high for more
than 2,5 s.
•
The signal range is defined in MCF.
•
Abort program and display error.
•
i44
code: Pressure sensor signal too low
•
The error is set if the sensor signal is out of range, signal low for more than
2,5 s.
•
The signal range is defined in MCF.
•
Abort program and display error.
•
i45
code: Calibration invalid, pressure signal too low
•
The warning is set if the sensor signal is out of range for an empty dw,
signal low.
•
The signal range for calibration is defined in MCF.