14
Installation manual
The washer extractor is prepared for connection of external dosing systems or water re-use systems etc.
The connections are closed at delivery.
• Open the connections (A) that shall be used by drilling a
⌀
17 mm hole where the hoses shall be connected. Any
extra required adapters which are field supplied can be used.
NOTE!
Make sure there is no burrs left after drilling.
• Connect the hose from the right side of the Jetsave pumps unit to the connection to be used on the washer
extractor.
• Mount the rubber adapter, rubber bushing, clamps, hose from pumps unit to the connection (A) according to the
following figure.
• Tighten clamps (B) with torque 3 Nm (2.2 lbf.ft).
A
B
fig.X02360
If the hoses are made of a soft material such as silicone or similar, make sure the hose size isn't reduced, isn't sharp
bended and is fitted properly to the washer extractor (A). Previous figure isn't valid for the soft hose.
NOTE!
Equipment for external dosing must only be connected to work on pump pressure
and not on network pressure.