12
Installation manual
NOTE!
The check valves (D) are supplied detached in a bag with the unit. To prevent dam-
age, do not install hoses to the check valve while connected to the manifold.
D
FL
1
2
3
4
fig.X02362
Warning
Do not connect any chemical hose to the (FL) flush position.
Cut the hose to the length needed.
Push the hose (E) on to the check valve (D) and secure with a cable tie. Connect the elbow (F) to the manifold and
secure with the white clip (G).
F
G
2
3
D
E
1
fig.X01357