Installation manual
If more Jetsave systems shall be used the next one shall be paired to the third row etc.
Up to three Jetsave systems can be used and paired.
5.5
Priming the pumps
• Enter the Advance manager password or Advance service password to access the Main menu.
• Activate the Pumps menu.
• Activate the Priming menu.
• Activate Pump 1 from the list to start priming the first pump.
• Press play to start priming and press stop when ready. (You can also use the pairing button (C) to start and stop,
or button (J) and (K) for 6-10 pumps products).
The hose shall be filled all they way to the outlet of the hose.
Do the same for all the pumps.
5.6
Calibrating the pumps
• Enter the Advance manager password or Advance service password to access the Main menu.
• Activate the Pumps menu.
• Activate the Calibration menu.
• Activate P1 from the list to start calibrating the first pump.
The different steps to be made when calibrating will now be visible on the screen.
1. Fill a container with ml markings (minimum volume 350 ml) with the product to be calibrated and place the tube
from the Jetsave system to be calibrated into the container.
2. Press play to start calibrating.
3. Press stop when 250 ml has been removed from the container.
4. Save the result for the pump.
The first pump has now been calibrated.
Do the same for all the pumps.
Note!
You can also use the pairing button (C) to start and stop the calibration, or button (J) and (K) for 6-10 pumps
products.
250 ml
fig.8052B