background image

iConserve User Guide___________________________________________________  

                                             

 

Transmitter Coupler onto each main wire. There may be a ground wire that’s gray or white; 
you’ll want to skip this wire. Just attach each sensor around the live wires only. If you’re 
interested in just monitoring one appliance such as you’re a/c or water heater, just install a 
coupler to that particular devices power feed in the breaker box. Most household electricity 
breaker panel’s use single-phase, however some larger homes or townhomes can use three-
phase. Most standalone business buildings will use three-phase. Note for three-phase the 
iConserve unit is required to have a sensor connected to each of the three-phase live main 
power cables. We offer two sensor sizes 10mm and 16mm. You will only use one size and at 
most use three sensors (called 3 Phase) at one time. If you’re not sure how many you need to 
use or what size please consult your electric company or a local certified electrician.  
 
As shown in the example, once the live main power cable is found clip the transmitter’s coupler 
sensor around the insulated live main power cable. **DO NOT TOUCH OR CLIP THE SENSOR 
AROUND RAW METAL OR UNINSULATED WIRING. ** The sensor coupler can be clipped 
anywhere along the insulated live main power cable, exact location doesn’t matter. Just try and 
clip it on a bend in the cable so it simply rests on the bend and nothing else is interfered with.  
 

 

 
 

Installing batteries for both Transmitter and Main Display Unit 

 

  Remove the battery cover from the back of the transmitter or display unit. 

  Insert AA batteries into the battery compartment ensuring that the polarities of the 

batteries are in the correct position.  

  Replace the battery cover of the transmitter or display unit. 

 
 

Link display unit and transmitter 

 
Press the “SEARCH” button of the display unit and then the “TRANSMIT” button (the only 
button on the transmitter) of the transmitter to link the communications between the display unit 
and the transmitter. Keep the units at arm’s length in distance for initial connection. 
 
 

Operating Guide 

 

Setting time and date 

 
Press the “TIME” button and hold for 2 seconds to enter the year setting. The last two numbers 
of the year digits will flash. Press the “FWD/BWD” button to increase or reduce the number. 
Press and hold the “FWD/BWD” button for the number to increase and reduce quickly. 
 

Summary of Contents for iConserve

Page 1: ...sensor in your breaker box or power source for your home or business FIRST consult with a local Certified Electrician In addition it s highly recommended that you hire this Certified Electrician to safely and properly install these components Inappropriate contact with your breaker box or main power source can be FATAL Table of Contents Introduction 2 Features 2 Overview 2 Display unit 2 Transmitt...

Page 2: ... save money and you will also help the planet A cost saving of up to 15 percent is possible with iConserve Features Display instant and total energy cost and CO2 emissions View hourly daily weekly and monthly electricity data Historical graphical chart of electricity usage Time view clock day week month and year High amount of electricity warning alarms automatically Data storage capacity 2 years ...

Page 3: ...Receiving signal indicator 3 Battery low indicator 4 Alert icons to warn of 30 or higher of usual daily consumption level of electricity 5 Accumulative historical energy cost CO2 emission data 6 The histogram of energy cost CO2 emissions for last seven months weeks days hours 7 The display for current real time energy cost CO2 emission readings 8 Clock and Calendar 9 Cost tariff rate 10 Money curr...

Page 4: ...ensor around the insulated live main power cable DO NOT TOUCH OR CLIP THE SENSOR AROUND RAW METAL OR UNINSULATED WIRING The sensor coupler can be clipped anywhere along the insulated live main power cable exact location doesn t matter Just try and clip it on a bend in the cable so it simply rests on the bend and nothing else is interfered with Installing batteries for both Transmitter and Main Dis...

Page 5: ... FWD BWD button to set the hour in the 24 hour Military Time Format Press the TIME button again to activate the minute setting The digits of the minutes will flash Press the FWD BWD button to set the minutes Press the TIME button to save the settings and then to return to the normal display Throughout the set up process press the ENTER button at any time to save settings instantly and to return to...

Page 6: ... of day or night For example before 6PM its 0 045 per kilo watt hour KWH and after its 0 09 per kilo watt hour KWH until 1AM To enable this function press the MODE button again to set the current tariff also known as Tier TARIFF1 or Tier1 will start flashing Press the FWD BWD buttons to set the use of two tariff standards Again your power company may call these Tier1 and Tier2 If you choose TARIFF...

Page 7: ...or local electrician to confirm View instant and accumulative energy cost CO2 In normal display mode you can view current power kW on the right screen and the accumulated energy kWh Press the MODE button to see the COST display You can view the current cost of electricity per hour on the right screen and accumulated cost since you last reset it on the right screen Press the MODE button again to se...

Page 8: ...n to see the historical data shown by the per week mode Use the BWD FWD button to look up the usage of energy for the last 7 weeks The corresponding block in the histogram will start to flash Press the HISTORY button again to see the historical data shown by per month mode Use the BWD FWD button to look up the usage of energy for the last 24 months The histogram will show the data of the current u...

Page 9: ...ill return to the normal display with a leaf symbol on the screen which is notifying you that the energy alarm is enabled and active When the alarm is triggered a new icon will appear and the unit will beep for 2 minutes and display will continuously blink MUST READ When installing the sensor and when in doubt always consult a certified electrician Do not immerse the unit in water or other liquids...

Page 10: ...r 2 as our rate for tariff 1 tier 1 in our iConserve s configuration and tariff 2 tier 2 would be left blank or not enabled at all My Cost reading doesn t match my monthly electric bills actual cost The iConserve provides an estimated cost based data you provide it Some power companies have various charges that cannot be figured out by the iConserve because they are additional fees such as Electri...

Page 11: ...Mode for 10 seconds Then configure your unit to 110V voltage Let the unit sit for 7 days recording energy usage On the seventh day select the Day historic chart Ignore day 0 and day 6 and write down the numbers for day 1 2 3 4 5 Use a calculator to add these figures you wrote down together then divide them by 5 This figure is the average usage in your home for a period of 5 days Multiply this numb...

Page 12: ...n display unit and transmitter working normally A being the main display unit B being the transmitter unit Normal Status will look like A LCD display with functional beeping buttons when pressed B LED flashes 1 blink up to 64 seconds on transmitter Quick press on Check Link button On the side of the transmitter unit Every 64 seconds the LED s should blink Potential Problems Problem for A No displa...

Page 13: ...erence as much as possible Or turn off the interfering signal source if possible Solution for C Replace batteries if power is low I m using two iConserve units and I m confused as to which display unit belongs to which transmitter Exercise process of elimination Place the receiver close to the transmitter and then pull out the sensor plug from the transmitter for some time to view the receiver pow...

Page 14: ...her parameters are correct on the main display unit What s a quick step by step process oh how to setup operate the iConserve for advanced users 1 If you are using this product for the first time we suggest you do the following steps Step 1 Load batteries into the receiver and set the current time Step 2 Set the local voltage electricity rates and other parameters Step 3 Load the batteries into th...

Page 15: ...3 Setting for the daily capacity alarm value and on off alarm function manually 4 Voltage Setting 100V to 250V According to local standards users can set it by manual 5 Maximum record capacity four digits 9999KWH over will show HI 6 Automatically calculates the CO2 excretion Greenhouse gas CO2 0 45kg kWH nkWH factory default is 0 45kg for each 1kWh power consumption According to local standards us...

Page 16: ...e attempting to install the transmitter and clamp sensor in your breaker box or power source for your home or business FIRST consult with a local Certified Electrician In addition it s highly recommended that you hire this Certified Electrician to safely and properly install these components Inappropriate contact with your breaker box or main power source can be FATAL All information and instructi...

Reviews: