This total number we’ll use as our tariff 1 / tier 1 rate on our main display unit in the 
configuration setup mode. We will enter 0.135 (since you’re limited to a total of 3 decimal 
numbers passed the decimal point) 
 
With these settings and similar electric bill, your total energy expenses will be to your iConseve 
when compared to your actual bill. 
 

My KWH usage per month doesn’t match my actual monthly energy bill’s KWH usage per 
month?  

Depending on your specific power companies measurements and states legal regulatory 
measurements there may be an offset. For example your home may be a 2 phase (also known 
as 3 phase) which will more than likely bring in 220v into your home or business. You may need 
to set the iConserve to 150v or 185v or other. We recommend to first resetting your display units 
energy data the night before the first billing day of your electric bill. Then setting the display unit 
to 110v(most homes) or 220v(most businesses) then allowing it to record exactly the number of 
billing days for that month 28-31 calendar days (depending on the month you’re in). When this 
month ends, now check your electric bill online or wait for it in the mail. If your bill records 1200 
KWH used for that specific month, then adjust the voltage on the iConserve to match the KWH 
of your energy bill. Keep setting the unit plus or minus to various voltage settings until it’s close 
to your bill. It will now provide a reasonably accurate reading. 
 

A more difficult yet quicker alternative to locating your homes exact voltage: 

First reset your main display unit’s memory by holding down buttons “History” and “Mode” for 10 
seconds. Then configure your unit to 110V voltage. Let the unit sit for 7 days recording energy 
usage. On the seventh day select the Day historic chart. Ignore day “0” and day “-6” and write 
down the numbers for day -1,-2,-3,-4,-5. Use a calculator to add these figures you wrote down 
together then divide them by 5. This figure is the average usage in your home for a period of 5 
days. Multiply this number by the number of days billed on your electric bill for your last month’s 
bill. This might be called “Days in Bill Period” or “Days in Billing Cycle” or similar. This figure will 
give you your total estimated usage according to the iConserve. It will be off plus of minus. If it’s 
above your bills usage reading, then lower the units 110 voltage by increments of 5 and keep 
doing the same math above until near your bills usage reading. If it’s below your energy bill, 
then do the same thing as above only increase the voltage on your iConserve from 110 to 115 
and do the math again. Keep doing this in increments of 5 and you’ll eventually come to a very 
close reading to that of your energy bills. 
 

Which sensor coupler size should I use? 

 

That depends on your breakers live main power wire’s size. Some are 10mm and some are 
16mm. It’s ok for the sensor coupler to be loose over the wire; it’s not ok for the sensor coupler 
to be too small for the cable. The coupler needs to be clipped (closed) completely around the 
wire.  
  

Why is the display blank?

 

This may be due to the batteries. Ensure that the batteries are inserted correctly and that they 
are not exhausted. 
 

Why is there a “0.00” reading on the display? 

This means that the sensor is not able to measure anything. There could be a couple of 
reasons. Check if the sensor coupler is properly secured around the cable. Check if the sensor 
is plugged into the transmitter. Another possibility is if the sensor was dropped the ferrite core of 

Summary of Contents for iConserve

Page 1: ...sensor in your breaker box or power source for your home or business FIRST consult with a local Certified Electrician In addition it s highly recommended that you hire this Certified Electrician to safely and properly install these components Inappropriate contact with your breaker box or main power source can be FATAL Table of Contents Introduction 2 Features 2 Overview 2 Display unit 2 Transmitt...

Page 2: ... save money and you will also help the planet A cost saving of up to 15 percent is possible with iConserve Features Display instant and total energy cost and CO2 emissions View hourly daily weekly and monthly electricity data Historical graphical chart of electricity usage Time view clock day week month and year High amount of electricity warning alarms automatically Data storage capacity 2 years ...

Page 3: ...Receiving signal indicator 3 Battery low indicator 4 Alert icons to warn of 30 or higher of usual daily consumption level of electricity 5 Accumulative historical energy cost CO2 emission data 6 The histogram of energy cost CO2 emissions for last seven months weeks days hours 7 The display for current real time energy cost CO2 emission readings 8 Clock and Calendar 9 Cost tariff rate 10 Money curr...

Page 4: ...ensor around the insulated live main power cable DO NOT TOUCH OR CLIP THE SENSOR AROUND RAW METAL OR UNINSULATED WIRING The sensor coupler can be clipped anywhere along the insulated live main power cable exact location doesn t matter Just try and clip it on a bend in the cable so it simply rests on the bend and nothing else is interfered with Installing batteries for both Transmitter and Main Dis...

Page 5: ... FWD BWD button to set the hour in the 24 hour Military Time Format Press the TIME button again to activate the minute setting The digits of the minutes will flash Press the FWD BWD button to set the minutes Press the TIME button to save the settings and then to return to the normal display Throughout the set up process press the ENTER button at any time to save settings instantly and to return to...

Page 6: ... of day or night For example before 6PM its 0 045 per kilo watt hour KWH and after its 0 09 per kilo watt hour KWH until 1AM To enable this function press the MODE button again to set the current tariff also known as Tier TARIFF1 or Tier1 will start flashing Press the FWD BWD buttons to set the use of two tariff standards Again your power company may call these Tier1 and Tier2 If you choose TARIFF...

Page 7: ...or local electrician to confirm View instant and accumulative energy cost CO2 In normal display mode you can view current power kW on the right screen and the accumulated energy kWh Press the MODE button to see the COST display You can view the current cost of electricity per hour on the right screen and accumulated cost since you last reset it on the right screen Press the MODE button again to se...

Page 8: ...n to see the historical data shown by the per week mode Use the BWD FWD button to look up the usage of energy for the last 7 weeks The corresponding block in the histogram will start to flash Press the HISTORY button again to see the historical data shown by per month mode Use the BWD FWD button to look up the usage of energy for the last 24 months The histogram will show the data of the current u...

Page 9: ...ill return to the normal display with a leaf symbol on the screen which is notifying you that the energy alarm is enabled and active When the alarm is triggered a new icon will appear and the unit will beep for 2 minutes and display will continuously blink MUST READ When installing the sensor and when in doubt always consult a certified electrician Do not immerse the unit in water or other liquids...

Page 10: ...r 2 as our rate for tariff 1 tier 1 in our iConserve s configuration and tariff 2 tier 2 would be left blank or not enabled at all My Cost reading doesn t match my monthly electric bills actual cost The iConserve provides an estimated cost based data you provide it Some power companies have various charges that cannot be figured out by the iConserve because they are additional fees such as Electri...

Page 11: ...Mode for 10 seconds Then configure your unit to 110V voltage Let the unit sit for 7 days recording energy usage On the seventh day select the Day historic chart Ignore day 0 and day 6 and write down the numbers for day 1 2 3 4 5 Use a calculator to add these figures you wrote down together then divide them by 5 This figure is the average usage in your home for a period of 5 days Multiply this numb...

Page 12: ...n display unit and transmitter working normally A being the main display unit B being the transmitter unit Normal Status will look like A LCD display with functional beeping buttons when pressed B LED flashes 1 blink up to 64 seconds on transmitter Quick press on Check Link button On the side of the transmitter unit Every 64 seconds the LED s should blink Potential Problems Problem for A No displa...

Page 13: ...erence as much as possible Or turn off the interfering signal source if possible Solution for C Replace batteries if power is low I m using two iConserve units and I m confused as to which display unit belongs to which transmitter Exercise process of elimination Place the receiver close to the transmitter and then pull out the sensor plug from the transmitter for some time to view the receiver pow...

Page 14: ...her parameters are correct on the main display unit What s a quick step by step process oh how to setup operate the iConserve for advanced users 1 If you are using this product for the first time we suggest you do the following steps Step 1 Load batteries into the receiver and set the current time Step 2 Set the local voltage electricity rates and other parameters Step 3 Load the batteries into th...

Page 15: ...3 Setting for the daily capacity alarm value and on off alarm function manually 4 Voltage Setting 100V to 250V According to local standards users can set it by manual 5 Maximum record capacity four digits 9999KWH over will show HI 6 Automatically calculates the CO2 excretion Greenhouse gas CO2 0 45kg kWH nkWH factory default is 0 45kg for each 1kWh power consumption According to local standards us...

Page 16: ...e attempting to install the transmitter and clamp sensor in your breaker box or power source for your home or business FIRST consult with a local Certified Electrician In addition it s highly recommended that you hire this Certified Electrician to safely and properly install these components Inappropriate contact with your breaker box or main power source can be FATAL All information and instructi...