A: Protocol Data Points for EIG Meters
Doc# E204701 A-29
Electro
Industries/GaugeTech
™
Powered by Innovation™
Point
Name
BACnet
Object
Type
BACnet
Object
ID
N2
Data
Type
N2
Point
Address
EIP
Tag
Name
DF1
Address
Lon
Name
Lon
SNVT
W
Ͳ
hours
Received
Meter
24
AI
314
ADF
58
S32_XXX[191]
F12:191
nvoWHRecM24_XXX
SNVT_count_inc_f
W
Ͳ
hours
Delivered
Meter
22
AI
315
ADF
59
S32_XXX[192]
F12:192
nvoWHDelM22_XXX
SNVT_count_inc_f
W
Ͳ
hours
Delivered
Meter
23
AI
316
ADF
60
S32_XXX[193]
F12:193
nvoWHDelM23_XXX
SNVT_count_inc_f
W
Ͳ
hours
Delivered
Meter
24
AI
317
ADF
61
S32_XXX[194]
F12:194
nvoWHDelM24_XXX
SNVT_count_inc_f
W
Ͳ
hours
Net
Meter
22
AI
318
ADF
62
S32_XXX[195]
F12:195
nvoWHNetM22_XXX
SNVT_count_inc_f
W
Ͳ
hours
Net
Meter
23
AI
319
ADF
63
S32_XXX[196]
F12:196
nvoWHNetM23_XXX
SNVT_count_inc_f
W
Ͳ
hours
Net
Meter
24
AI
320
ADF
64
S32_XXX[197]
F12:197
nvoWHNetM24_XXX
SNVT_count_inc_f
W
Ͳ
hours
Total
Meter
22
AI
321
ADF
65
S32_XXX[198]
F12:198
nvoWHTotM22_XXX
SNVT_count_inc_f
W
Ͳ
hours
Total
Meter
23
AI
322
ADF
66
S32_XXX[199]
F12:199
nvoWHTotM23_XXX
SNVT_count_inc_f
W
Ͳ
hours
Total
Meter
24
AI
323
ADF
67
S32_XXX[200]
F12:200
nvoWHTotM24_XXX
SNVT_count_inc_f
VAR
Ͳ
hours
Positive
Meter
22
AI
324
ADF
68
S32_XXX[201]
F12:201
nvoVARhPsM22_XXX
SNVT_count_inc_f
VAR
Ͳ
hours
Positive
Meter
23
AI
325
ADF
69
S32_XXX[202]
F12:202
nvoVARhPsM23_XXX
SNVT_count_inc_f
VAR
Ͳ
hours
Positive
Meter
24
AI
326
ADF
70
S32_XXX[203]
F12:203
nvoVARhPsM24_XXX
SNVT_count_inc_f
VAR
Ͳ
hours
Negative
Meter
22
AI
327
ADF
71
S32_XXX[204]
F12:204
nvoVARhNgM22_XXX
SNVT_count_inc_f
VAR
Ͳ
hours
Negative
Meter
23
AI
328
ADF
72
S32_XXX[205]
F12:205
nvoVARhNgM23_XXX
SNVT_count_inc_f
VAR
Ͳ
hours
Negative
Meter
24
AI
329
ADF
73
S32_XXX[206]
F12:206
nvoVARhNgM24_XXX
SNVT_count_inc_f
VAR
Ͳ
hours
Net
Meter
22
AI
330
ADF
74
S32_XXX[207]
F12:207
nvoVARhNtM22_XXX
SNVT_count_inc_f
VAR
Ͳ
hours
Net
Meter
23
AI
331
ADF
75
S32_XXX[208]
F12:208
nvoVARhNtM23_XXX
SNVT_count_inc_f
VAR
Ͳ
hours
Net
Meter
24
AI
332
ADF
76
S32_XXX[209]
F12:209
nvoVARhNtM24_XXX
SNVT_count_inc_f
VAR
Ͳ
hours
Total
Meter
22
AI
333
ADF
77
S32_XXX[210]
F12:210
nvoVARhToM22_XXX
SNVT_count_inc_f
VAR
Ͳ
hours
Total
Meter
23
AI
334
ADF
78
S32_XXX[211]
F12:211
nvoVARhToM23_XXX
SNVT_count_inc_f
VAR
Ͳ
hours
Total
Meter
24
AI
335
ADF
79
S32_XXX[212]
F12:212
nvoVARhToM24_XXX
SNVT_count_inc_f
VA
Ͳ
hours
Total
Meter
22
AI
336
ADF
80
S32_XXX[213]
F12:213
nvoVAhTotM22_XXX
SNVT_count_inc_f
VA
Ͳ
hours
Total
Meter
23
AI
337
ADF
81
S32_XXX[214]
F12:214
nvoVAhTotM23_XXX
SNVT_count_inc_f
VA
Ͳ
hours
Total
Meter
24
AI
338
ADF
82
S32_XXX[215]
F12:215
nvoVAhTotM24_XXX
SNVT_count_inc_f
Positive
Watts
Meter
01
Avg
AI
339
ADF
83
Flt_XXX[122]
F10:122
nvoPsWtM1Avg_XXX
SNVT_count_inc_f
Positive
Watts
Meter
02
Avg
AI
340
ADF
84
Flt_XXX[123]
F10:123
nvoPsWtM2Avg_XXX
SNVT_count_inc_f
Positive
Watts
Meter
03
Avg
AI
341
ADF
85
Flt_XXX[124]
F10:124
nvoPsWtM3Avg_XXX
SNVT_count_inc_f
Positive
VARs
Meter
01
Avg
AI
342
ADF
86
Flt_XXX[125]
F10:125
nvoPsVARM1Av_XXX
SNVT_count_inc_f
Positive
VARs
Meter
02
Avg
AI
343
ADF
87
Flt_XXX[126]
F10:126
nvoPsVARM2Av_XXX
SNVT_count_inc_f
Positive
VARs
Meter
03
Avg
AI
344
ADF
88
Flt_XXX[127]
F10:127
nvoPsVARM3Av_XXX
SNVT_count_inc_f
Negative
Watts
Meter
01
Avg
AI
345
ADF
89
Flt_XXX[128]
F10:128
nvoNgWtM1Avg_XXX
SNVT_count_inc_f
Negative
Watts
Meter
02
Avg
AI
346
ADF
90
Flt_XXX[129]
F10:129
nvoNgWtM2Avg_XXX
SNVT_count_inc_f
Negative
Watts
Meter
03
Avg
AI
347
ADF
91
Flt_XXX[130]
F10:130
nvoNgWtM3Avg_XXX
SNVT_count_inc_f
Negative
VARs
Meter
01
Avg
AI
348
ADF
92
Flt_XXX[131]
F10:131
nvoNgVARM1Av_XXX
SNVT_count_inc_f